7

Finishing

A. Facing Material
The fireplace structure can be covered with any non-
combustible material. Refer to Section 1.D.
It is possible for the face of the appliance above the ap-
pliance opening to show signs of soot. It is recommend-
ed that a noncombustible ledge (shelf) approximately 3
inches above the opening and a minimum of 3 inches out
from the face of the appliance incorporated into the facing
material will help prevent soot from going up the wall.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specified in this
manual. Overlapping materials could ignite. Any instal-
lation outside the scope as stated in this manual please
contact your authorized HHT dealer prior to installation.
CAUTION! The motorized power screen is located di-
rectly behind the Lower Access Panel. When installing
facing material DO NOT screw into the labeled areas as
damage to the screen will occur. See Figure 7.1.
DO NOT screw
in this area
Figure 7.1 Screen Location
22
Outdoor Lifestyles by Hearth & Home Technologies • Palazzo Installation Manual • 4082-311 Rev. A • 06/08/15
B. Mantel and wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be con-
structed entirely of noncombustible materials (i.e., steel
studs, concrete board, etc.).
Figure 7.2 and 7.3 show the dimensions for mantels or
other combustible projections above the appliance open-
ing.
Top View of
Appliance
Mantel Leg or Perpendicular Wall
A 2 in. (51mm) min. from edge of
appliance to perpendicular wall (one
side only). Alcove installations require
9 in. (229mm) from edge of appliance.
B
7 in. (178mm) min. from fireplace
opening to perpendicular wall (one
side only). Alcove installations require
14 in. (355mm) from each side of the
firebox opening.
Figure 7.2 Mantel Leg or wall Projections
Cement Board
A
B

Advertisement