2.8 Connection of power cable
2.8
2.8
2.8
Connection of power cable
Connection of power cable
Connection of power cable
To reach the power terminal board remove the left side of the appliance. Loosen the cable-
clamp on the back (at the bottom) of the appliance (see Fig. 1) and pass the cable through up
to near to the terminal board. Locate the leads against the terminal board so that the earth lead
is the last to detach from its terminal in the event of reverse pulling.
Connect the 3 phase
phase leads to the terminals marked "1"
phase
phase
terminal marked " " " " 4 4 4 4 " " " " or "5"
following layout:
(this electrical connection layout is also available near the power supply terminal board). Tighten
the cable clamp on the back (at the bottom) of the appliance and replace the left side. The
cable must correspond to those given in the "Technical specifications" table (paragraph 1.1).
The appliance must be connected to an equipotential system
according to current regulations.
This connection must be made between different appliances using the special terminal
marked with
. The equipotential lead must have a minimum diameter of 2,5mm
equipotential terminal is on the rear of the appliance.
2.9 Connection to water mains
2.9
2.9
2.9
Connection to water mains
Connection to water mains
Connection to water mains
The oven must be supplied with softened drinking water with a hardness value of 0.5 to 5°F
(It is obligatory to use water softener to reduce the formation of scaling inside the boiler). The
water pressure must be in the range of 150 to 250 kPa (1.5 – 2.5 bar). If the water pressure
exceeds 2.5 bar, install a pressure reducer device upstream. If the pressure is below 1.5 bar, use
a pressure pump to increase the level.
The connection to the water supply is done using the ¾" threaded solenoid valve on the
back (at the bottom) of the appliance (see fig. 1), fitting a mechanical filter with a cut-off cock
(before connecting the filter, allow a certain amount of water to flow out in order to remove
any waste from the pipe).
N.B.: The water supply system must never be emptied when the boiler is operating. If necessary
N.B.:
N.B.:
N.B.:
turn the appliance off and let it cool before emptying the water supply system
_________________________________________________________________________________________ page 9 _
"5"
"5" and the earth
"5"
earth
earth lead to the terminal marked
earth
380
380- - - - 400V~3
380
380
400V~3N N N N
400V~3
400V~3
1
2
3
equipotential system after checking its efficiency
equipotential system
equipotential system
"1" "2"
"2" and " " " " 3 3 3 3 " " " " , the neutral
"1"
"1"
"2"
"2"
4
5
neutral lead to the
neutral
neutral
as shown in the
. The
2
.

Advertisement

loading