SW7:
Lifted hopper micro-switch
SW8:
Open hopper micro-switch
SW9:
Closed hopper micro-switch
SW10:
Filter-shaker micro-switch
SW11:
Horn switch
SW12:
Hood microswitch
SW13:
Working light switch (optional)
SPK:
Petrol engine ignition spark plug
VR1:
Petrol engine voltage regulator
Colour code
BK:
Black
BU:
Blue
BN:
Brown
GN:
Green
GY:
Grey
OG:
Orange
PK:
Pink
RD:
Red
VT:
Violet
WH:
White
YE:
Yellow
Hopper lifting system hydraulic diagram
(See Fig. AG)
1.
Hydraulic oil tank
2.
Hydraulic oil filter
3.
Hydraulic pump
4.
Engine
5.
Lifting cylinder safety valve
6.
Hopper lifting cylinder
Drive system hydraulic diagram
(See Fig. AH)
1.
Hydraulic oil tank
2.
Hydraulic oil filter
3.
Hydraulic pump
4.
Hydraulic motors

ELECTRICAL FUSES

Under the hood, protected by a transparent plastic cover
(3, Fig. V), there are the following fuses to protect the
related circuits:
– F1 fuse (40A) (right side of the machine): Key (main)
– F2 fuse (15A): Alternator
– F3 fuse (30A): filter-shaker
– F4 fuse (30A): Hopper/filter-shaker lifting hydraulic
pump
– F5 fuse (10A): Hopper lifting hydraulic pump actuator
– F6 fuse (10A): Horns/working lights/hour counter
– F7 fuse (40A): Spare fuse
– F8 fuse (30A): Spare fuse
146 2603 000(1)2005-03 A
USER MANUAL

ACCESSORIES/OPTIONS

In addition to the standard components, the machine can
be equipped with the following accessories/options,
according to the machine specific use:
Left side broom;
Main and side brooms with harder or softer bristles;
Antistatic polyester or polyester BIA C dust filter;
Pocket filter;
Pivoting light;
Working light;
Non marking skirt;
Non marking wheels;
Protective roof.
For further information concerning the optional
accessories, contact an authorised Service Center or
Retailer.

USE

WARNING!
On some points of the machine there are
some adhesive plates indicating:
– DANGER
– WARNING
– CAUTION
– NOTE
While reading this Manual, the Operator must pay
particular attention to these symbols.
Do not cover these plates for any reason and immediately
replace them if they are damaged.

BEFORE START-UP

1.
If necessary, open the hood (1, Fig. V), unscrew the
plug (9) and refuel the machine.
CAUTION!
Do not fill the petrol tank to less than 4 cm
from the filling opening to leave room for
the gasoline to expand.
2.
Check that there are no open doors/hoods and that
the machine is in normal operating conditions.
3.
If the machine has not been used yet after the
transportation, check that each block and locking
system used for the transportation have been
removed.
ENGLISH