SIDE
VIEW
TOP
VIEW
Figure 1. Clamp connection to stud adapter
Figure 2. Clamp connection to stud pad
Testing the Battery Pack
1. Connect the red clamp to the positive (+) lug on the battery at
one end of the pack (Figure 3).
2. Connect the black clamp to the negative (–) lug on the battery at
the other end of the pack.
3. For a proper connection, rock the clamps back and forth. Both
sides of the clamp must be firmly connected before testing. If the
message CHECK CONNECTION appears, clean the terminals
and/or reconnect the clamps.
Figure 3. Clamp connections to lugs
2
•
•