BATTERY TEST RESULTS

The Micro700 will display the open circuit voltage, cranking amps
based on the units are based on rating system you selected, and
one of five battery decisions. The analyzer also generates a battery
code that you can view separately. Refer to "Viewing the Battery Test
Code."
GOOD BATTERY
The battery is in good condition. Return to service.
GOOD-RECHARGE
Fully charge the battery. Return to service.
CHARGE & RETEST
Fully charge the battery, remove the surface charge, and retest.
Failure to fully charge the battery before retesting may cause false
readings.
REPLACE BATTERY
A battery evaluated as "replace" may still start the vehicle, but it no
longer measures up to its minimum standard and will fail soon.
BAD CELL-REPLACE
Replace the battery and retest to perform a complete system
analysis
IMPORTANT: A REPLACE BATTERY result may mean a poor
connection exists between the vehicle's cables and the battery. After
disconnecting the vehicle's cables from the battery, retest the battery
using the Out-Of-Vehicle Test before replacing.

Testing the Next Battery

The display will alternate between the test results and the message
CONNECT TO NEXT BATTERY. If you want to retest the battery or
test a new battery, connect the clamps and press ENTER when
instructed. The analyzer will ask you to enter only the rating system
and rating value before displaying the next result.
IMPORTANT: In the Out-of-Vehicle test the analyzer stores only the
last test result and battery test code for printing or later viewing. They
will be deleted when you connect the clamps again.