4.5 Connection to the mains

Connect the fixture to the mains with the enclosed power-plug.
The earth has to be connected!
The occupation of the connection-cables is as follows:

4.6 DMX-512 connection/connection between fixtures

The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with the
fixture or one fixture with another.
Occupation of the XLR-connection:
If you are using the standard DMX-controllers, you can connect the DMX-output of the controller directly with the
DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs,
you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Cable
Pin
Brown
Live
Light blue
Neutral
Yellow/Green
Earth
DMX - output
XLR mounting-socket:
1 - Ground
2 - Signal (-)
3 - Signal (+)
International
L
N
DMX-input
XLR mounting-plug:
9
1 - Ground
2 - Signal (-)
3 - Signal (+)
W
resistor