Fig. 27
ALC Channel Area
8.3.

Trigger Control

The following 5 types of Trigger Control are available by the combination of Trigger Selector, Trigger
Mode, Exposure Mode and Trigger Option.
Table-20 Trigger control
Camera Settings
Trigger
Selector
Trigger
Mode
Frame
Off
Start
Off
On
On
On
8.3.1

Trigger Selector

Selects the trigger operation. In the GO-5000-PGE, the following trigger operation can be
selected as the trigger.
Table-21 Trigger selector
Trigger Selector Item
Frame Start
Acquisition Start
Acquisition End
Acquisition Transfer Start
Each trigger has the following setting parameters and those parameters are configured on each
trigger selector item.
Setting parameters: Trigger Mode, Trigger Software, Trigger Source, Trigger Activation
GO-5000M-PGE / GO-5000C-PGE
High
Left
Mid-High
Left
Mid-Low
Left
Low
Left
JAI Custom
Trigger Mode
Trigger
Name
Option
Exposure
Mode
Continuous
Off
Off
Trigger
Continuous
Timed
Off
Trigger
Timed
Off
EPS Trigger
Timed
RCT
RCT Trigger
Trigger
Off
PWC Trigger
Width
Description
Frame Start Trigger operation
Acquisition Start Trigger operation
Acquisition End Trigger operation
Transfer Trigger operation
High
High
High
Mid-left
Mid-right
Right
Mid-High
Mid-High
Mid-High
Mid-left
Mid-right
Right
Mid-
Mid-Low
Mid-Low
Low
Mid-left
Mid-right
Right
Low
Low
Low
Mid-left
Mid-right
Right
Description
Free-running
maximum exposure time per the frame
rate
Free-running operation with a user-set
exposure time.
Externally triggered operation with a
user-set exposure time
Externally triggered operation for RCT
Externally triggered operation with a
pulse width exposure time
- 41 -