7.2.3

Exposure Auto

This is a function to control the exposure automatically. It is effective only for Timed.
JAI ALC Reference controls the brightness.
There are three modes, OFF, Once and Continuous.
OFF:
Once:
Continuous:
In this mode, the following settings are available.
ALC Speed:
ASC Max:
ASCMin: The minimum value for the exposure time to be controlled can
ALC Reference:
ALC Channel area:
Associated GenICam register
GenICam
Name
Exposure
Auto
Exposure
Auto Max
Exposure
Auto Min
7.3.

Trigger Control

7.3.1

Trigger Source

The following signals can be used as the trigger source signal.
OFF
Line 5 (Input to Opt In 1 and output from Digital IO
Line 4 (Input to TTL In1 and output from Digital IO
User Out 0 to 3
Trigger Packet IN
Soft Trigger
Pulse Generator 0 to 3
NAND1/NAND2
7.3.2

Trigger activation

This command can select how to activate the trigger.
Rising Edge:
Falling Edge:
Level High:
Level Low:
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
SP-5000M-CXP2 / SP-5000C-CXP2
No exposure control
Exposure adjusts when the function is set, then remains at that setting
Exposure continues to be adjusted automatically
Rate of adjustment can be set
The maximum value for the exposure time to be controlled can
be set
be set
The reference level of the exposure control can be set
The measurement area of the exposure control can be set
Access
Values
Off
R/W
Continuous
Once
100
to
R/W
1000000
100
to
R/W
1000000
At the rising edge of the pulse, the trigger is activated.
At the falling edge of the pulse, the trigger is activated.
During the high level of trigger, the accumulation is activated
During the low level of trigger, the accumulation is activated
Category
Acquisition Control
JAI-Custom
JAI-Custom