Physis Piano H1 Reference Manual page 39

V100
Hide thumbs Also See for H1:
Table of Contents

Advertisement

 
Program Change
Selects Sounds or Memories, in combination with Control Change 0
(Bank Select MSB).
Data format:
n=channel number:
mm=Program Change number:
Make sure that the Program Change number is 1 unit less
than the Sound or Memory number. So, location 1 is recalled
by PC 0, location 2 by PC 1, etc.
When selecting Memories, Bank Select MSB and Program
Change messages are sent on Part1 channel only. However,
data can be received on Part1 or Part2 channels.
Pitch Bend
Controls the Pitch Bend effect for the HDSE Sounds.
Data format:
n=channel number:
vv=value:
This message is transmitted when HDSE Pitch Up or HDSE
Pitch Down functions are assigned to a foot pedal.
SYSTEM MESSAGES
System Exclusive
Device Inquiry
Instrument information sent after switching on and when a Device
Inquiry Request is received.
Data format: F0H 7EH 00H 06H 02H 31H 00H 1CH 20H
00H xxH yyH zzH vvH F7H
F0H: Exclusive status
7EH: Universal Non Realtime message
00H: channel
06H: general information
02H: device ID reply
31H: Viscount ID
00H 1CH: device family code
20H 00H: device family member code
xxH yyH zzH vvH: software version
F7H: End of Exclusive
This message is only transmitted.
Device Inquiry Request
Request for Device Inquiry message.
Data format: F0H 7EH 7FH 06H 01H F7H
F0H: Exclusive status
7EH: Universal Non Realtime message
7FH: channel (any)
06H: general information
01H: device ID request
F7H: End of Exclusive
This message is only received.
Master Fine Tuning
This message controls the Fine Tuning parameter of the TUNING
function under the FUNCTION menu.
Data format: F0H 7FH 7FH 04H 03H vvH nnH F7H
F0H: Exclusive status
7FH: Universal Realtime message
7FH: channel (any)
04H: Sub-ID #1=Device Control message
03H: Sub-ID #2=Master Fine tuning
CnH mmH
00H – 0FH (1 – 16)
00H – 7FH (0–127)
EnH vvH
00H – 0FH (1 – 16)
00H – 7FH (0–127)
37
vvH nnH: fine tuning value
00H 00H: A4=415,3 Hz
00H 40H: A4=440 Hz
7FH 7FH: A4=466,2 Hz
F7H: End of Exclusive
Temperament
Selects the Temperament as in the Tuning function of FUNCTION
menu.
Data format: F0H 7EH 7FH 08H 08H 03H 7FH 7FH [ss]
... F7
F0H: Exclusive status
7EH: Universal Non Realtime message
7FH: channel (any)
08H: Sub-ID #1=MIDI Tuning standard
08H: Sub-ID #2=scale/octave tuning 1-byte form
(Non Real-Time)
03H: channel/options byte 1
7FH: channel byte 2
7FH: channel byte 3
[ss]:12 byte tuning offset of 12 semitones from C
to B
00H: -64 cents
40H: 0 cents
7FH: +64 cents
System Realtime
Timing Clock (F8H)
This message is transmitted and recognized to synchronize Physis
Piano's metronome with other MIDI devices. It is transmitted 24
times per quarter note. It is always transmitted, while the reception
has to be enabled through the Metronome function.
Start (FAH)
This message is transmitted when the sequencer starts to
play/record. In order to start playing/recording from another MIDI
device, reception has to be enabled though the Metronome
function.
Pause/Continue (FBH)
This message is transmitted when the sequencer pauses and
restarts playing/recording. In order to pause playing/recording
from another MIDI device, reception has to be enabled though the
Metronome function.
Stop (FCH)
This
message
is
transmitted
playing/recording. In order to stop playing/recording from another
MIDI device, reception has to be enabled though the Metronome
function.
Active Sensing (FEH)
Once Active Sensing has been received, if no MIDI data is
received for more than approximately 200 milliseconds, the
instrument will perform the same function as if All Sounds Off, All
Notes Off and Reset All Controllers messages had been received
and the system stops checking FEH.
Manuale di Riferimento – MIDI
when
the
sequencer
stops

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Physis Piano H1

This manual is also suitable for:

H3H2

Table of Contents