Table 8. Power-supply LEDs
Power-supply LEDs
ac
dc
Error
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
On
Off
Off
On
Off or
On
Flashing
On
On
Off
On
On
On

Internal LEDs, connectors, and jumpers

The illustrations in this section show the LEDs, connectors, and jumpers on the
internal boards. The illustrations might differ slightly from your hardware.
140
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual
Description
Action
No ac power to
1. Check the ac power to the server.
the server or a
2. Make sure that the power cord is
problem with the
connected to a functioning power
ac power source
source.
3. Turn the server off and then turn the
server back on.
4. If the problem remains, replace the
power supply.
No ac power to
1. Replace the power supply.
the server or a
2. Make sure that the power cord is
problem with the
connected to a functioning power
ac power source
source.
and the power
supply had
detected an
internal problem
Faulty power
Replace the power supply.
supply
Faulty power
Replace the power supply.
supply
Power supply not
1. Reseat the power supply.
fully seated,
2. If the system board error LED is off,
faulty system
replace the power supply.
board, or faulty
3. (Trained service technician only) If the
power supply
system board error LED is on, replace
the system board.
Faulty power
Replace the power supply.
supply
Normal operation
Power supply is
Replace the power supply.
faulty but still
operational
Notes
This is a normal
condition when no
ac power is present.
This happens only
when a second
power supply is
providing power to
the server.
Typically indicates
that a power supply
is not fully seated.