Recovering From A Lenovo Thinkserver Server Firmware Update Failure - Lenovo THINKSERVER 3822 Hardware Maintenance Manual

Lenovo server user manual
Table of Contents

Advertisement

Recovering from a Lenovo ThinkServer Server Firmware update failure

If power to the server is interrupted while you are updating the Lenovo ThinkServer
Server Firmware, the server might not restart correctly or might not display video. If
this happens, complete the following steps to recover:
122
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual
1. Read the safety information that begins on page 5.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Unlock and remove the side cover (see "Removing the left-side cover" on page
157).
4. Locate JP6 on the system board and remove any adapters that impede access
to the jumpers.
Table 5. System-board jumpers
Jumper
Jumper
number
name
1
JP6
UEFI boot
recovery
2
JP1
CMOS
clear
3
SW6
switch
block
Note: If no jumper is present, the server responds as if the pins are set to 1
and 2.
5. Move jumper JP6 to pins 2 and 3 to enable the UEFI recovery mode.
6. Replace any adapters that you removed; then, install the side cover (see
"Installing the left-side cover" on page 158).
7. Reconnect all external cables and power cords.
8. Insert the update CD into the CD or DVD drive.
9. Turn on the server and the monitor.
After the update session is completed, remove the CD from the drive and turn
off the server.
Jumper setting
v Pins 1 and 2: Normal operation (default).
v Pins 2 and 3: Enable the UEFI recovery mode.
v Pins 1 and 2: Normal operation (default).
v Pins 2 and 3: Clears CMOS.