Function Of Auto-Toner Sensor - Toshiba e-STUDIO167 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO167:
Table of Contents

Advertisement

12.5.2

Function of auto-toner sensor

1) Function
-
Initialization adjustment function - At the first use of the equipment or when the developer mate-
rial is replaced with a new one.
Automatically adjusts the output value of the auto-toner sensor responding to humidity (input
value to the A/D converter) for the toner density of the new developer material so that it stays in
range of 2.34 to 2.46 V.
-
Stabilizing the toner density - During the printing operation
Maintains the toner density to a certain ratio as follows.
Toner is consumed.
o The toner density is lowered.
o Change in the auto-toner sensor output responding to humidity is detected.
o The toner motor is driven.
o Toner is supplied from the toner cartridge to the developer unit.
-
Toner-empty detection and recovery:
Detects that there is no toner in the toner cartridge:
The toner motor is driven.
o The auto-toner sensor output does not change.
o The toner density does not change.
o It is determined there is no toner in the cartridge (toner empty).
Recovering from the toner-empty state:
The toner motor is driven.
o Toner is supplied from toner cartridge.
o The auto-toner sensor output changes.
o The toner density returns to normal value.
o The toner-empty state is cleared.
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
12 - 9
e-STUDIO167/207/237
DEVELOPMENT SYSTEM
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio237E-studio207

Table of Contents