Disassembly And Replacement - Toshiba e-STUDIO167 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO167:
Table of Contents

Advertisement

6.7

Disassembly and Replacement

[A] Original glass
(1)
Remove 2 rubber caps and 2 screws, take off
the original glass holder while sliding it to the
right.
Note:
The rubber caps are not installed in the
equipment for NAD, CND, AUD, TWD, KRD
and ARD.
(2)
Remove 2 rubber caps and 2 screws, take off
the original glass.
Notes:
1. When handling the original glass, take
care not to contaminate the surface with
fingerprints or such.
2. Do not place the original glass directly on
the floor.
3. When installing the original glass, fit 2
guides of the original glass in the groove
of the scanner top cover.
4. The rubber caps are not installed in the
equipment for NAD, CND, AUD, TWD,
KRD and ARD.
(3)
Take off the ADF original glass.
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
Rubber cap
Fig. 6-12
Rubber cap
Fig. 6-13
ADF Original glass
Fig. 6-14
6 - 17
07/03
Original glass holder
Original glass
e-STUDIO167/207/237
SCANNER
6