1.3.8 Installation of Drain Piping
(1).
not remain trapped inside the pipe.
(2).
(3). Install the drain piping as shown and take measures against condensation. Improperly rigged piping
could lead to leaks and eventually wet furniture and belongings.
Extension drain piping
(commercially available)
1.3.9 Installing the Drain Pipes
(1). Insert the drain pipe to the drain outlet of the unit and then tighten the clamp securely with tape.
(2). Connect the extension drain pipe to the drain pipe and then tighten the clamp with tape.
Tighten the clamp until the screw
head is less then 4mm from the hose.
Metal clamp
Drain hose (accessory)
Grey tape (accessory)
(3).
whose gauge is suitable for the operating capacity of the unit.(take the cassette type unit for example)
Model
A
670
950
950
1040
Insulating tube
(commercially
available)
B
C
D
596
592
571
840
780
680
840
777
708
910
842
788
Insulate the pipe clamp and the drain
hose using heat insulation sponge.
Metal clamp (accessory)
Insulation sponge (accessory)
drain pipes
E
F
145
240
160
240
160
320
170
290
Insulating tape
(accessory)
1
2
3
Indoor unit
drain hose