Sinclair ASGE-09AIN WK Service Manual page 127

New uni dc inverter series outdoor units asge-xxain wk indoor units-floor-ceiling, cassette, duct type
Table of Contents

Advertisement

Remark: Make sure that the power supply is cut off before disassembling and protect all the parts during disassembly.
Step
plate sub-assy for air
sweeping fans
Disassembly of fan and motor components
Remark: Make sure that the power supply is cut off before disassembling and protect all
the parts during disassembly, especially the fastening screws for fans.
Step
1. Disassembly of front
and back scroll cases
Disassembly of fan and motor components
Remark: Make sure that the power supply is cut off before disassembling and protect all
the parts during disassembly, especially the fastening screws for fans.
Step
2. Disassembly of fans
3. Disassembly of
4. Disassembly of motor
Remark: Make sure that the power supply is cut off before disassembling and protect all the parts during disassembly.
Step
Disassembly of right
Illustration
Illustration
Illustration
Illustration
Handling Instruction
Remove the display board, mounting support
and mounting plate of swing motor in turn.
Handling Instruction
Press the buckle at the joints of front and back
scroll cases with hands and pull upward to remove
the front scroll case. Then remove the screws on
the back scroll case. Lift the buckle of back scroll
case with hands and remove it. (As is shown in the
graph, circle represents 2 screws on left and right.)
Handling Instruction
Unscrew the 2 screws of coupling, take out
the rotating shaft and louver, then loosen the
tighten screw of louver to remove the louver.
Unscrew the 3 screws and 2 nuts of support
to remove the mounting support
Loosen the 2 screws of the motor attaching clamp,
remove the motor attaching clamp and motor
attaching clamp subassembly to remove the motor.
Handling Instruction
with tools. (As is shown by the arrow in the graph.)
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents