(1). Mode 1 (LCD displays 00)
(2). Mode 2 (LCD displays 01)
Note:
Mode 1: Compressor electric heating belt starts when outdoor ambient temperature is below 35°C and
stops when outdoor ambient temperature is above 37°C. When outdoor ambient temperature is within
35°C~ 37°C, the belt will keep its previous operation state.
Mode 1: Compressor electric heating belt starts when outdoor ambient temperature is below -2°C and stops
when outdoor ambient temperature is above 0°C. When outdoor ambient temperature is within -2°C~0°C,
the belt will keep its previous operation state.
4.9.7 Selecting low-power consumption mode
(1). With low-power consumption mode (LCD displays 00)
(2). Without low-power consumption mode (LCD displays 01)
4.9.8 Selecting door control function
(1). Without door control function (LCD displays 00)
(2). With door control function (LCD displays 01)
4.9.9 Selecting human sensitive function
(1). Without human sensitive function (LCD displays 00)
(2). With human sensitive function (LCD displays 00)
4.9.10 Selecting long-distance monitoring or centralized controller
(1). Centralized controller (LCD displays 00)
(2). Long-distance monitoring (LCD displays 01)
4.9.11 Selecting fan mode of indoor fan motor
(1). P3 (LCD displays 03)
(2). P4 (LCD displays 04)
(3). P5 (LCD displays 05)
(4). P6 (LCD displays 06)
(5). P7 (LCD displays 07)
Note: You can select P03, P04, P05, P06, P07 in fan mode of indoor fan motor, which means different fan
mode combinations are corresponding to different static pressure. Ex-factory defaulted mode is P05. You can
set the mode through wired controller. S01, S02, S03......S12, S13 means the rotation speed of indoor unit is
from low to high.
Static
Super high
pressure
speed
selection
P03
S09
P04
S10
P05
S11
P06
S12
P07
S13
4.9.12 Selecting compensation of temperature sensor at air return
(1). Compensate 0°C (LCD displays 00)
(2). Compensate 1°C (LCD displays 01)
(3). Compensate 2°C (LCD displays 02)
Table 2-4-2 Combination relationship of P03, P04, P05, P06, P07
Medium
High speed
high speed
S08
S07
S09
S08
S10
S09
S11
S10
S12
S11
Medium
Medium
Low speed
speed
low speed
S06
S05
S07
S06
S08
S07
S09
S08
S10
S09
Quiet
Quiet
R1 speed
R2 speed
S04
S03
S05
S04
S06
S05
S07
S06
S08
S07
Quiet
R13 speed
S02
S01
S03
S02
S04
S03
S05
S04
S06
S05
28