Sinclair ASGE-09AIN WK Service Manual page 27

New uni dc inverter series outdoor units asge-xxain wk indoor units-floor-ceiling, cassette, duct type
Table of Contents

Advertisement

When setting the filter clean reminder function, timer zone will display 2 digits, of which the former
indicates the pollution degree of operating place and the latter indicates the accumulated operating time of
indoor unit. There are 4 types of situations:
(1).
(2). Slight pollution: the former digit in timer zone shows 1 while the latter one shows 0, which indicates the
accumulated operating time is 5500hr. Each time the latter digit increases 1, the accumulated operating time
increases 500hr. When it reaches 9, it means the accumulated operating time is 10000hr;
(3). Medium pollution: the former digit in timer zone shows 2 while the latter one shows 0, which indicates the
accumulated operating time is 1400hr. Each time the latter digit increases 1, the accumulated operating time
increases 400hr. When it reaches 9, it means the accumulated operating time is 5000hr;
(4). Heavy pollution: the former digit in timer zone shows 3 while the latter one shows 0, which indicates the
accumulated operating time is 100hr. Each time the latter digit increases 1, the accumulated operating time
increases 100hr. When it reaches 9, it means the accumulated operating time is 1000hr;
The detailed pollution level and the corresponding time is as shown in Table 2-4-1 below:
Pollution level
operating time (hour)
10
11
12
13
14
15
16
17
18
19
Table 2-4-1 Pollution level and corresponding time
Accumulated
Pollution level
5500
6000
6500
7000
7500
8000
8500
9000
9500
10000
Accumulated
operating time (hour)
20
1400
21
1800
22
2200
23
2600
24
3000
25
3400
26
3800
27
4200
28
4600
29
5000
Accumulated
Pollution level
operating time (hour)
30
31
32
33
34
35
36
37
38
39
100
200
300
400
500
600
700
800
900
1000
25