Cooling And Heating Data Sheet In Rated Frequency; Noise Curve - Gree GWH12MB-K3DNE3G Service Manual

Table of Contents

Advertisement

Service Manual

2.4 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(°C) (DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated heating
condition(°C) (DB/WB)
Indoor
Outdoor
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.

2.5 Noise Curve

Indoor side noise when blowing
45
40
35
30
25
Supper High
Indoor fan motor rotating speed
Technical Information
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09K
0.9~1.1
12K
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09K
2.2~2.4
12K
High
Middle
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
12 to 15
65 to 38
11 to 14
64 to 37
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
35 to 63
2 to 5
35 to 65
2 to 5
Outdoor side noise when Compressor speed changed
55
50
45
20
Low
Fan speed of
Fan speed of
indoor unit
outdoor unit
TURBO
High
Fan speed of
Fan speed of
indoor unit
outdoor unit
TURBO
High
30
40
50
Compressor Speed(rps)
Compressor
revolution (rps)
54
60
Compressor
revolution (rps)
62
66
09K
12K
60
70
75
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh09mb-k3dne3g

Table of Contents