12-16
LS 4208 Product Reference Guide

UPC-E1 Preamble

Preamble characters are part of the UPC symbol consisting of Country Code and System Character. Three options are given for
transmitting UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code
("0"
for USA), and no preamble transmitted. Scan a bar code below to match the host system.
System Character & Country Code
(< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)

Convert UPC-E to UPC-A

Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data
follows
UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
When disabled, UPC-E decoded data is transmitted as UPC-E data, without conversion.
*
Do Not Convert UPC-E to UPC-A
No Preamble
(<DATA>)
(Disable)
*
System Character
(<SYSTEM CHARACTER> <DATA>)

Convert UPC-E to UPC-A

(Enable)

Advertisement