Issue
Pilot and burner
extinguish while in
operation
Soot appears on glass
Flame burns blue and lifts
off burner
No reaction to command
Cause
No LP (propane) gas in tank
Incorrect glass assembly
installation
Incorrect vent cap installation
Vent cap blockage
Exhaust vent pipe leaking
exhaust gases back into firebox
Incorrect glass media
installation
Improper venturi setting
Incorrect vent cap installation
Vent cap blockage
Improper venturi setting
Incorrect vent cap installation
Blockage or leakage of the vent
system
Battery back batteries or
remote control batteries low
No communication between
remote control and IFC module
A maximum number of failed
ignitions or flame restorations
has been reached
Check LP (propane) tank. Refill if necessary.
Refer to Section 9.1 Glass Assembly on page 21.
Adjust if necessary.
Remove debris if necessary.
Check for leaks and repair if necessary.
Refer to Section 9.3 Glass Media Installation on page 21.
Venturi air shutter may need to be opened slightly to allow more air
into the gas mix. Refer to Section 12.2.1.1 Venturi Adjustment on
page 31.
Adjust if necessary.
Remove debris if necessary.
Venturi air shutter may need to be opened slightly to allow more air
into the gas mix. Refer to Section 12.2.1.1 Venturi Adjustment on
page 31.
Adjust if necessary.
Check the vent pipes for leaks, and the vent cap for debris. Repair
the vent pipes or remove debris from vent cap, if necessary.
Replace batteries.
Reprogram remote control to IFC module (See Section 11.2 on page
25).
Rest IFC module (See Section 11.6 on page 26).
Solution