Problems during bootup

The following sections describe problems you might encounter during power
on self-test (POST) or during bootup sequence of the enclosure and explains
how to resolve those problems. POST shows problems related to the processor,
logic, and memory.
Symptom
One of the POST diagnostic
tests failed.
The system hangs at CT_srv
starting.
The system hangs during a
drive scan.
Solution
Contact Gateway Technical Support.
Follow these steps to resolve the problem:
Verify that there are no SCSI address conflicts.
Check the enclosure to make sure everything is correctly
connected.
If the enclosure and the drive work correctly, replace the
controller.
Follow these steps to resolve the problem:
Check the enclosure to make sure everything is correctly
connected.
Remove and replace the drive that failed the scan.
If the enclosure and the drive work correctly, replace the
controller.