MINUTO
Action by user
Switch on Steam Button LED
ERROR: Led Steam Button remains off,
check the interface board and fl at cable
(JP21)
Action by user
Switch on Hot Water Button LED
ERROR: Led Hot Water Button remains off,
check the interface board and fl at cable
(JP21)
Finish condition: NO BU, NO drag drawer,
Door open, No Water in tank, Coffee Beans
cover open
Level 2 (Input)
Start condition: NO BU, NO drag drawer, Door open, No
Water in tank, Coffee Beans cover open
Action by user
Switch off Red Leds NoWater
ERROR: Led NoWater remains on, check the capacitive
sensor (fi xing) and the wiring (JP23)
Action by user
Switch off Red Leds GenAlarm
ERROR: Led GenAlarm remains on, check the BU presen-
ce Microswitch and the wiring (JP16).
Press Steam Button
Press Steam Button
Led
NoBeans
OFF
Press BUTTON ON/OFF to move to the next screen
Press BUTTON ON/OFF to move to the next screen
Insert a full Water Tank
Insert the Brew Unit
LED INDICATION
Led Steam Button
ON
OFF
LED INDICATION
Led Steam Button
OFF
OFF
LED INDICATION
Led
Led
NoWater
GenAlarm
OFF
OFF
Led
NoBeans
NoWater
ON
Led
NoBeans
NoWater
NA
NA
Led
NoBeans
NoWater
NA
NA
05 TROUBLESHOOTING
Led HotWater Button
OFF
OFF
Led HotWater Button
ON
OFF
Led
Led
Dreg
Descale
OFF
OFF
LED INDICATION
Led
Led
GenAlarm
ON
ON
LED INDICATION
Led
Led
GenAlarm
OFF
NA
ON
NA
LED INDICATION
Led
Led
GenAlarm
NA
OFF
NA
ON
Led
Rinsing
OFF
Led
Dreg
ON
Led
Dreg
NA
NA
Led
Dreg
NA
NA
Page
/ 46