MINUTO
7.5.1 Two-way solenoid valve
Remove the board support
assembly and disconnect
the electric connection
Two-way solenoid valve in Minuto Cappuccino
7.5.2 Carafe connection and hot water dispenser in Minuto Cappuccino
Slide out the fork
as illustrated
7.6.
Pin boiler
Loosen the screws holding
the solenoid valve to the
upper plate
Disconnect all elec-
trical and water
circuit connections
Loosen the screws holding
the carafe connection
Loosen the screws as illustrated and
remove the boiler pin (A).
Disconnect all electrical and water
circuit connections
When reassembling the assembly to be
careful to correctly position the spring.
07 DISASSEMBLY
Page
/ 09
05