ModemCOM-TM2
6.
6.1 Data transferring
„ModemCOM/G10" supports bearers presented below. Which data type is used depends on
GSM operator and data transfer capacity in the chosen GSM Network.
6.2 Mechanical specifications
„ModemCOM/G10" housing is made of metal. It is light and durable – suitable for using in
home, office or industrial environment. The external dimensions and measures of the unit casing are:
100*60*31 mm.
6.3 Electrical and operating specifications
Acceptable voltage range is (6 ÷ 32)V DC. 9 V is a nominal value. The PC the
„ModemCOM/G10" modem is connected to must have a RS232 (COM) interface.
Note: The device must be powered with AC/DC adapter provided by manufacturer.
Electrical parameters of the device are shown in the Table 1.
Parameter
Power Supply
Average Power consumption
Maximum Power consumption
TECHNICAL SPECIFICATIONS
•
GPRS class 10 (class B);
•
CSD;
•
CSF;
•
SMS textual messages.
Table 1. Electrical parameters of the device
1
Min
+6V
0.58A
+9V
-
-
User' Manual v2.1.1.19
Typical
0.39A
+32V
480 mW
3500 mW
Max
0.1A
-
-
6