CLEARANCES WHEN BUILT-IN

MINIMUM 3/8" (10mm) CLEARANCE TO TOP
OF APPLIANCE( combustible or non-combustible)
MINIMUM 1" (25.4mm) CLEARANCE TO
SIDES AND BACK OF APPLIANCE
(combustible or non-combustible)
The fireplace insert may be placed within a framed enclosure that is level, dry, and capable of supporting the weight of the appliance
and front glass. It may be placed directly on wood or a non-combustible surface (not on linoleum or carpet). The minimum clearance
from the top of the appliance to a mantel (combustible or non-combustible) is 2" (50.8mm). The sides and back must maintain 1" (25.4mm)
clearance to any material. The top must maintain a 3/8" (10mm) clearance to any material.

UNPACKING AND TESTING THE FIREPLACE INSERT

Carefully remove the fireplace insert from the box.
Remove the packing screws from both sides of the insert
(see illustration to the right). Prior to installing the
fireplace insert, plug the unit into a 120-volt grounded
outlet and test operation. Test all aspects of its
operation (manual switches, remote, display
characteristics and heater) to make sure all components
operate correctly.
MANTEL(maximum 12" (305mm) deep
WALL
2"[50.8 mm]
FRONT GLASS
APPLIANCE
SIDE VIEW
FLOOR
7