Daikin Super multi NX E Series Service Manual page 134

Hide thumbs Also See for Super multi NX E Series:
Table of Contents

Advertisement

Control Specification
Detail
The followings are the examples of the outdoor electronic expansion valve control which
function in each operation mode.
Operation pattern
When power is turned on
Cooling, 1 room operation
Cooling, 2 rooms operation to
Cooling, 4 rooms operation
Stop
Heating, 1 room operation
Heating, 2 rooms operation
Stop
Heating operation
Control of discharge pipe
thermistor disconnection
Stop
1 : When all the indoor units are operating, "liquid pipe temperature control" is conducted.
2 : "SC (subcooling) control" is conducted for the operating indoor units, when some of the units are not operating.
3 : "Liquid pipe temperature control for stopped room" is conducted for the non-operating indoor units.
123
: Holding Functions
— : No Functions
Fully closed when power is turned on
Open control when starting
(Control of target discharge pipe
temperature)
Control when the operating room is
changed
(Control of target discharge pipe
temperature)
Pressure equalizing control
Open control when starting
(Control of target discharge pipe
temperature)
Control when the operating room is
changed
(Control of target discharge pipe
temperature)
(Defrost control)
Pressure equalizing control
Open control when starting
Continue
Pressure equalizing control
2
2
2
SiBE121135_A
1
3
1
3
1
3
(R16007)
Function and Control

Advertisement

Table of Contents
loading

Table of Contents