Daikin FXVQ125MY1 Installation Manual
Daikin FXVQ125MY1 Installation Manual

Daikin FXVQ125MY1 Installation Manual

Floor standing duct type

Advertisement

MODELS
Floor standing duct type
FXVQ125MY1
FXVQ200MY1
FXVQ250MY1
FXVQ400MY1
FXVQ500MY1
FXVQ500MY16
CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

INSTALLATION MANUAL

SYSTEM Air Conditioners

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FXVQ125MY1

  • Page 1: Installation Manual

    INSTALLATION MANUAL SYSTEM Air Conditioners MODELS Floor standing duct type FXVQ125MY1 FXVQ200MY1 FXVQ250MY1 FXVQ400MY1 FXVQ500MY1 FXVQ500MY16 CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
  • Page 2: Table Of Contents

    Installation VRV System FXVQ125MY1 FXVQ200MY1 FXVQ250MY1 FXVQ400MY1 FXVQ500MY1 FXVQ500MY16 manual air conditioner CONTENTS Failure to use the specified parts may result in the air conditioner falling down, water leakage, electric shocks, a SAFETY PRECAUTIONS ..........1 fire, etc. 2. BEFORE INSTALLATION ..........2 •...
  • Page 3: Before Installation

    • Install the air conditioner, power supply wiring, remote Name Bolts (for flanges) controller wiring and transmission wiring at least 1 14 pcs. 30 pcs. 18 pcs. 36 pcs. meter away from televisions or radios to prevent image Quantity (125 · 200 type) (250 type) (400 type) (500 type)
  • Page 4: Carry-In Method

    4. INSTALLATION SITE 2. Items to be checked at delivery Check Note Items to be checked column Do not apply force on the resin parts in case of carrying the Have you carried out field setting? (if necessary) indoor unit when and after unpacking. Are the control box lid, the air filter and the suction grille attached? (1) Select an installation site where the following conditions...
  • Page 5: Caution At Installation

    5. CAUTION AT INSTALLATION TENSION OF V BELT • Tension of a V belt must meet the deflection load (W) as shown. HOW TO REPLACE PULLEY Calculate the required deflection length (L) by the equation <125-250 type> (1), its tolerance must be within the range as below. (1) Remove the suction grille.
  • Page 6: Piping Connection

    HOW TO WORK THE REFRIGERANT 6-4 PROCESSING METHOD OF CONNECTION PIPING PIPING Remove the pinched pipings brazed to the end of the internal • See the following table for the Processing connection piping. piping. Braze and connect the standard accessory piping. •...
  • Page 7: Drain Piping

    <125-250 type> Downward inclination More than 40 mm 1/100 or more Indoor unit Unit bottom line Drain plug cap Drain plug (accessories) Connection piping Drain trap Refrigerant Gas piping (Accessory) make a piping insulation Insulation for drain trap (Field supply) More than 40 mm drain plug (accessories)
  • Page 8 <Method of wiring for the wiring between indoor unit <400 · 500 type> and outdoor unit, the earth wiring and the power supply Wiring from right side wiring> Earth terminal for shield wire Terminal block for the (1) Remove the front panel (lower). wiring between indoor Terminal block for unit and outdoor unit...
  • Page 9: Electrical Characteristics

    • Do not carry out soldering finish when stranded wires are Voltage Model Volts MCA TOCA MFA kW FLA used. (Otherwise, the loosening of wires may result in range abnormal heat radiation.) FXVQ125MY1 16 0.75 1.9 FXVQ200MY1 FXVQ250MY1 Max. 456V 50 Hz 380- 415V Min. 342V...
  • Page 10: Field Setting And Control Wiring

    Transmission wiring UNIT NO. MODE NO. Model Field fuses Wiring Size Wiring Size SECOND FIELD CODE NO. UNIT NO. FXVQ125MY1 MODE FIRST FXVQ200MY1 Wiring size SETTING Balanced CODE NO. and length FXVQ250MY1 H05VV type shield 0.75 − 1.25 must comply...
  • Page 11: Trial Operation

    REMOTE CONTROLLER AND 10. TRIAL OPERATION CENTRALIZED CONTROL (1) Confirm that the control box lid of the indoor units and the <When operating forced OFF or ON/OFF control from the outdoor unit are closed. terminal block (X3M)> (2) Perform the test run according to the installation manual Method of wiring and specifications attached to the outdoor unit.
  • Page 12 3P345056-4F EM13A004B [1511] HT...

This manual is also suitable for:

Fxvq200my1Fxvq250my1Fxvq500my1Fxvq500my16Fxvq400my1

Table of Contents