Daikin Super multi NX E Series Service Manual page 59

Hide thumbs Also See for Super multi NX E Series:
Table of Contents

Advertisement

SiBE121135_A
Signal Receiver /
Display PCB
1) S51
2) S52
3) S1W
4) H1P
5) H2P
6) JA
Caution
Replace the PCB if you accidentally cut the jumpers other than JA.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
INTELLIGENT
EYE Sensor PCB
1) S36
Printed Circuit Board Connector Wiring Diagram
Connector for control PCB
Connector for room temperature thermistor
Forced cooling operation [ON/OFF] button
LED for operation (multi-color)
LED for INTELLIGENT EYE (green)
Address setting jumper
∗ Refer to page 253 for detail.
H2P
S51
S52
Connector for control PCB
H1P
JA
S1W
3P254832-1
S36
3P255914-1
Indoor Unit