Sony SAL135F18Z Service Manual page 74

Lens for dslr camera (sonnar 1.8/135 za) (sonnar t* 135mm f1.8 za)
Hide thumbs Also See for SAL135F18Z:
Table of Contents

Advertisement

4-10. FOCUS HOLD BUTTON CHECK (FOCUS HOLD BUTTON SHORT)
Equipment
• Personal Computer
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker)
1. Preparations
1) Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2) Start up of "ActuatorChecker".
[Set up]
3) Click
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
[Focus Hold Button Short]
1) Click the
2) The Serial window appears. Input the lens serial number.
Note:
[OK]
When
is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-10-2
3) The message "Move FOCUS to Near position. Then push [ENTER]." is displayed on the pop-up window.
Set the focus to the near position and press down the ENTER key.
SAL135F18Z (Sonnar 1.8/135 ZA) (Sonnar T
.
Fig.4-10-1
Fig.4-10-3
135mm F1.8 ZA)
*
4-38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents