E.C.A. Proteus Plus Installatio And User's Operating Instructions page 7

23,3 kw room sealed fan assisted gas combination boiler (monothermic type)
Table of Contents

Advertisement

Table 2.2
Gas Category *
Boiler Type
Type of gas
Performances
P
, Min. Heat Output
min
P
, Max. Heat Output
maks
P
, Heat Output
%80
Q
, Min. Thermal Load
min
Q
, Max. Thermal Load
maks
Q
, Thermal Load
%80
Gas Consumption
Natural Gas (Max. Load)
Natural Gas (Min. Load)
LPG
Gas Supply Pressure
Natural Gas
LPG
Domestic Hot Water
Min. Flow Rate For Activating
Max. Flow Rate
Min. Operating Pressure
Max. Operating Pressure
Set Temperature Range
Central Heating
Min. Operating Pressure
Max. Operating Pressure
Set Temperature Range
General
Electrical Supply
Electrical Power Consumption
Expansion Vessel
Insulation Class
Dimensions (HxWxL)
Weight (Net)
NOx
For gas consumption calculation ; Natural gas: Hu=9,59 kWh/m
*the following gas categories can also be used
Gas Categories
PRP 24 HM
II
2H 3B/P
C
C
C
C
12x
32x
42x
52x
Natural gas
LPG
8,2
23,3
18,7
9,2
25,6
20,5
2,67
0,96
2,00
20
28 / 37
3
10 (t=33,4)
0,3 / 30
10 / 1
35-64
0,6
3
40-80
230V AC- 50Hz
95
8
IPX4D
720x400x330
35
2
LPG: Hu=12,793 kWh/kg
PRP 24 HM
II
2H 3B/P
II
2E 3B/P
II
2E+ 3+
Unit
kW
kW
kW
kW
kW
kW
3
m
/h
3
m
/h
kg/h
mbar
mbar
ltr/min
ltr/min
bar / kPa
bar/ MPa
o
C
bar
bar
o
C
V AC / Hz
watt
ltr
mm
kg
3
6

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proteus Plus and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF