PMW-F55 Warning and Error Messages

If a problem occurs on the PMW-F55, the following warning
and error messages may be displayed in the viewfinder.
For details about messages, refer to the PMW-F55 operating
instructions.
Message type
Message
Warning
CAM: TEMP HIGH
Error
CAM: Exx-xxx
(ex: E95-207)
Status
CAM: FAN
STOPPED
CAM: BACKUP
BATT END
CAM: OPT
LOWPASS
CAM: ABNORMAL
LENS
CAM: PLEASE
EXEC ABB
46
Appendix
Meaning
The internal temperature is
abnormally high.
A hardware or other error
occurred.
The cooling fan stopped
abnormally.
The backup battery is low
on charge.
The optical lowpass filter
does not match the [High
Frame Rate Mode] setting.
The lens type setting and
the connected lens type are
different.
The ABB (auto black
balance) requires
adjustment.
F65 Warning and Error Messages
If a problem occurs on the F65, the following warning and error
messages may be displayed in the viewfinder.
For details about messages, refer to the F65 operating
instructions.
Message type
Message
Warning
CAM:
TEMPERATURE
CARE
CAM: 12V
BATTERY (NEAR
END)
CAM: 24V
BATTERY (NEAR
END)
CAM: OPTICAL
LEVEL CARE
Error
CAM: DIGITAL VF
ERROR
Status
CAM: 12V
BATTERY (END)
CAM: 24V
BATTERY (END)
CAM:
TEMPERATURE
NG!
CAM: FAN1 NG!
CAM: FAN2 NG!
CAM: SYNC
ERROR
CAM: OPTICAL
LEVEL NG!
CAM: OPTICAL
LEVEL NO INPUT
CAM: CRCC
ERROR
OCCURRED
CAM:
UNSUPPORTED
DIGITAL VF
CAM: M.SHUTTER
NG!
CAM: M.SHUTTER
NOT LOCKED
Meaning
The internal temperature of
the camera is close to the
upper limit.
The voltage of the 12 V
supply has fallen to the
specified Near End value.
The voltage of the 24 V
supply has fallen to the
specified Near End value.
The optical level received
on the SKC-4065 camera
connector has fallen to
critical level.
The DVF-EL100 has failed.
The voltage of the 12 V
supply has fallen to the
specified End value.
The voltage of the 24 V
supply has fallen to the
specified End value.
The internal temperature of
the camera has reached
the upper limit.
Fan 1 at the top has
stopped.
Fan 2 at the top has
stopped.
A sync error has occurred.
An optical level error has
occurred on the SKC-4065
camera connector.
There is no input signal on
the SKC-4065 camera
connector.
A CRCC error has occurred
on the SKC-4065 camera
connector.
A digital viewfinder other
than the DVF-EL100 is
connected.
The mechanical shutter
unit has failed.
The mechanical shutter
cannot be locked into
position.

Advertisement