Verifying Signal Strength; Example - Multitech MultiConnect Cell 100 Series MTC-EV3 User Manual

Table of Contents

Advertisement

CONFIGURING AND COMMUNICATING WITH YOUR DEVICE
Type AT and press Enter.
If the device responds with OK, you are communicating with the device.

Verifying Signal Strength

To verify the device signal strength, enter:
AT+CSQ
The command indicates signal quality, in the form:
+CSQ: <rssi>,<ber>
Where:
<rssi>
0
1
2-30
31
99
<ber>
0
1
2
3
4
5
6
7
99
Note:
Signal strength of 10 or higher is needed for successful packet data sessions.

Example

A example response to AT+CSQ:
+CSQ: 15,1
18
Received signal strength indication.
(-113) dBm or less
(-111) dBm
(-109) dBm - (-53) dBm / 2 dBm per step
(-51) dBm or greater
Not known or not detectable
Bit error rate, in percent
Less than 0.2%
0.2% to 0.4%
0.4% to 0.8%
0.8% to 1.6%
1.6% to 3.2%
3.2% to 6.4%
6.4% to 12.8%
More than 12.8%
Not known or not detectable
®