Display
5.14.2 Reset to factory settings
All special parameters saved by the user will be overwritten by the factory settings!
Operating
element
099-005319-EW501
22.05.2014
Setting/selection
Predefined execution of the pulsed arc welding process in the PA program
0 =
Predefined execution of the pulsed arc welding process in the PA program is
disabled.
1 =
If the superPuls and welding process switching functions are available and
activated, the pulsed arc welding process is always executed in the main
program PA (ex factory).
Predefined absolute value for relative programs
Start program (P
), down-slope program (P
START
relative to the main program (P
0 =
Relative parameter setting (ex factory)
1 =
Absolute parameter setting
Action
Result
Switch off welding machine
Keep the button pressed
Switch on welding machine
Release the button, wait about 3 seconds
Switch off welding machine and restart in order to put the changes into
effect
Design and function
Special parameters (advanced settings)
) and end program (P
B
) or in an absolute manner, as desired.
A
NOTE
) can be set
END
89