Matching The Cable Resistance - EWM Phoenix 355 Progress puls MM TKM Operating Instructions Manual

Hide thumbs Also See for Phoenix 355 Progress puls MM TKM:
Table of Contents

Advertisement

Design and function
Machine configuration menu

5.15.2 Matching the cable resistance

The resistance value of cables can either be set directly or it can be matched using the power source.
The factory setting of the power sources is 8 m-ohm. This value correponds to a 5 m earth cable, a 1.5 m
intermediate hose package and a 3 m water-cooled welding torch. With other hose package lengths, it is
necessary to carry out a +/- voltage correction to optimise welding properties. The voltage correction
value can be set close to zero by means of re-matching the cable resistance. It is recommended to match
the electric cable resistance after replacing accessories such as torches or intermediate hose packages.
In case a second wire feeder is used the (rL2) parameter has to be adjusted. For all other configurations it
is sufficient to match the (rL1) parameter.
1
0
2
3
4
100
l
+
0
l
B
A
Figure 5-58
50mm
099-005319-EW501