Field Wiring
11.0

DOMESTIC HOT WATER (DHW) PIPING

DHW Description of Operation

The VM110P (Vmax Plus) incorporates a Stainless Steel 16 gallon DHW storage tank with an internal Stainless
Steel heat exchanger coil (i.e. an Indirect Fired Hot Water Heater). This allows the Vmax Plus to heat DHW
without the need for a separate water heater. A temperature sensor continuously monitors the temperature of the
potable water in the tank, thereby ensuring that a constant supply of hot water is available. The tank temperature
can be adjusted via Installer Menu setting 2-07 ("DHW Setpoint"). Set "DHW Setpoint" to the desired hot water
temperature; to avoid the risk of scalding a Thermostatic Mixing Valve must be installed, see Figure 11-1.
VM110P DHW Plumbing & Set-up
DHW Connections – The VM110P has three potable water connections, Inlet/Drain, Outlet and Recirculation;
see Figure 11-1. If a recirculation line is not being used, be sure to cap the Recirculaiton connection on the
bottom of the Vmax Plus.
Throttling Valve – Use one of the isolation valves, installed hot water line, as a throttle valve to regulate the
maximum hot water flow rate. The VM110P has a limited firing rate (110 MBH); therefore excessive flow
rates will quickly deplete the hot water stored in the tank – recommend not to exceed 4 GPM.
Drain and Isolation Valves – Install drain and isolation valves on the cold water inlet and hot water outlet lines,
as shown in Figure 11-1, to allow for servicing of the storage tank and other potable water components. It may
be necessary to flush or clean the inside of the storage tank.
Recirculation Optional
(cap if not in use)
DHW Outlet (Hot)
Tempering Valve
(Check local codes)
DHW to Fixtures
Cold Water Supply
46
Figure 11-1 Near Boiler DHW Piping (VM110P)
Vmax I&O Manual
Condensate Drain
(install factory
supplied trap)
DHW Inlet (Cold)
Drain Valve
Isolation Valve

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vm110p

Table of Contents