Maintenance Port Parser Commands - KVH Industries TracVision G4 Technical Manual

Kvh industries satellitetelevision owner's manual tracvision g4
Hide thumbs Also See for TracVision G4:
Table of Contents

Advertisement

The diagnostics procedure requires Windows Hyperterminal (or
other terminal emulation software, such as PROCOMM). Use the
settings appropriate to your application.
1. Connect one end of the PC data cable to
the DB9 maintenance port connector on the rear of
the ADCU. Connect the other end to the serial port
on your PC (a 9-pin/25-pin connector adapter may
be needed for some PCs).
60 59
58
57
56
55
54
53
52
51
50
49
1
2
3
4
5
6
7
8
9
10
11
12
2. Open the terminal emulation software and
establish the following settings:
• 9600 baud
• no parity
• 8 data bits
• 1 start bit
• 1 stop bit
• no flow control
3. Apply power to the TracVision G4 system and
allow the system to complete full initialization.
Data should be scrolling on the PC display to
identify any system problems detected. If no data
is seen, recheck your connections and the terminal
software setup.
4.7
Maintenance Port Parser
Commands
TracVision G4 system parser commands are detailed in
Appendix H on page 151.
54-0147
48 47
46
45
44
43
42
41
40
39
38
37
13 14
15
16
17
18
19
20
21
22
23
24
25 26
Maintenance
Port (DB9)
27
28
29
30
31
32
33
34
35
36
Troubleshooting
Figure 4-2
ADCU Maintenance Port
Appendix F on page 143 shows the
diagnostic information available in
the startup data sequence.
99