FIGURE C
To Add Engine Oil:
1.
CAUTION! Your warranty is voided if you do not put engine oil in the
Engine's crankcase prior to its first use. Before each use, check the oil level.
Never run the Engine with low or no engine oil. Running the engine with low or
no oil will permanently damage the Engine.
2.
The Engine MUST be filled with a high quality grade engine oil. If the Engine will
be run in temperatures above 32 degrees Fahrenheit, use SAE 30 weight oil. If
the Engine will be run in temperatures below 32 degrees Fahrenheit, use SAE
5W-30 weight oil. (See Figure D, next page.)
To do so, unscrew and remove the Oil Dipstick (74). Pour engine oil into the
3.
Dipstick Hole until the level of oil is even with lower edge of the Dipstick Hole
(approximately 20 fluid ounces). (See Figure D.)
4.
Make sure to screw the Oil Dipstick (74) firmly back into its Dipstick Hole.
(See Figure D.)
To Fill The Fuel Tank:
1.
Prior to first using the Generator, the Fuel Tank (43) MUST be filled with high
octane unleaded gasoline (approximately 3.96 gallons). (See Figure D.)
2.
To do so, remove the Fuel Cap (44) and fill the Fuel Tank (43) with unleaded
gasoline. Then, replace the Fuel Cap. Thereafter, check the Fuel Gauge (47) for
SKU 95126
For technical questions, please call 1-800-444-3353

PRE-START INSTRUCTIONS

#12 AWG
GROUNDING WIRE
(NOT INCLUDED)
GROUND
TERMINAL
(10)
GROUNDING ROD
(NOT INCLUDED)
GROUNDING ROD
DRIVE
AT LEAST
24" DEEP
PAGE 11