Installation Instructions; Pre-Start Instructions - Chicago Electric 95960 Set Up, Operating, And Servicing Instructions

Generator set 16 hp - 7000/7500 watts
Table of Contents

Advertisement

5.
Secure the Axle (49) and Wheels (50) in place, using four Pins (51).
(See Assy. diagram.)
1.
iMPORTANT:
emergency or portable power systems. Make sure to investigate the local building
and electrical codes before installing this unit.
2.
Locate the Generator (outdoors only) where cooling air is readily available. Locate
the Generator so that the air inlets and outlets are not blocked by obstructions
such as bushes, trees, walls, snow drifts, etc. Locating the Generator in the path
of heavy winds may require the placement of a barrier for protection. The air inlet,
in normal weather conditions, should face the prevailing wind direction.
3.
Locate the Generator on a concrete slab or other area where rain drainage or flood
waters can not reach it.
4.
Generator placement should allow four feet of access to all sides for maintenance
and proper air cooling.
5.
Place the Generator as close as possible to the electrical tools and equipment be-
ing powered to reduce the length of extension cords.
6.
To ground the Generator, connect a #6 AWG grounding wire (not included) from
the Grounding Terminal (9) on the Control Panel to a grounding rod (not included)
that has been driven at least 24 inches deep into the earth. The grounding rod
must be an earth-driven copper or brass rod (electrode) which can adequately
ground the Generator. (See Figure c.)
1.
iMPORTANT: Your Warranty is voided if you do not put engine oil in the
Engine's crankcase prior to its first use. Before each use, check the oil level.
Never run the Engine with low or no engine oil. Running the Engine with no or low
engine oil WILL permanently damage the Engine.
SKU 95960
For technical questions, please call 1-800-444-3353.

iNSTALLATiON iNSTRucTiONS

Electrical and other permits may be required for the installation of
cONcRETE SLAB

PRE-START iNSTRucTiONS

FiGuRE c
GROuNdiNG TERMiNAL (9)
#6 AWG GROuNdiNG WiRE
(NOT iNcLudEd)
GROuNdiNG ROd
(NOT iNcLudEd)