Chicago Electric 94191 Assembly And Operation Instructions Manual

Chicago Electric 94191 Assembly And Operation Instructions Manual

Gas engine generator 13 hp

Advertisement

GAS ENGINE GENERATOR
ASSEMbly ANd OPERATION INSTRucTIONS
Due to continuing improvements, actual product may differ slightly from the product described herein.
you do not put engine oil in the Engine's crankcase prior to its first use.
Before each use, check the oil level. Never run the Engine with low or no engine oil.
Running the Engine with low or no oil will permanently damage the unit.
Visit our website at: http://www.harborfreight.com
TO PREVENT SERIOuS INjuRy, REAd ANd uNdERSTANd
All WARNINGS ANd INSTRucTIONS bEfORE uSE.
Copyright
2006 by Harbor Freight Tools
©
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor Freight Tools.
for technical questions or replacement parts, please call 1-800-444-3353.
13 HP
Model
your Warranty Is Voided If:
3491 Mission Oaks Blvd., Camarillo, CA 93011
94191
cAuTION!
. All rights reserved. No portion of this
®
®

Advertisement

Table of Contents
loading

Summary of Contents for Chicago Electric 94191

  • Page 1 . All rights reserved. No portion of this © ® manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. for technical questions or replacement parts, please call 1-800-444-3353.
  • Page 2: Specifications

    Power tools cre- ate sparks which may ignite the dust or fumes. REV 06l for technical questions, please call 1-800-444-3353. SKU 94191 Page 2...
  • Page 3: Personal Safety

    If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools. for technical questions, please call 1-800-444-3353. SKU 94191 Page 3...
  • Page 4: Specific Safety Rules And Precautions

    Maintain labels and nameplates on the Generator. These carry important infor- mation. If unreadable or missing, contact Harbor Freight Tools for a replacement. Make sure the Generator is located on a flat, level, sturdy surface capable of supporting the weight of the Generator and any additional tools and equip- ment.
  • Page 5: Fire And Explosion Precautions

    Avoid contact with hot fuel, oil, exhaust fumes, and solid surfaces. Avoid body contact with fuels, oils, and lubricants used in the Generator and Engine. If swallowed, seek medical treatment immediately. Do not induce vomiting for technical questions, please call 1-800-444-3353. SKU 94191 Page 5...
  • Page 6: Noise Precautions

    Abc fire extinguishers on electrical fires. unconditioned electrical output can damage sensitive equipment. Do not use to power sensitive electronic equipment without appropriate line conditioner (sold separately). for technical questions, please call 1-800-444-3353. SKU 94191 Page 6...
  • Page 7 It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. for technical questions, please call 1-800-444-3353. SKU 94191 Page 7...
  • Page 8: Assembly Instructions

    Connect the end of the Positive Battery Cable (63) to the Battery’s positive minal. Then connect the Negative Battery Cable (64) to the Battery’s negative (–) terminal. (See figure b.) REV 07h for technical questions, please call 1-800-444-3353. SKU 94191 Page 8...
  • Page 9: Installation Instructions

    Generator placement should allow four feet of access to all sides for maintenance and for proper air cooling. Place the Generator as close as possible to the electrical tools and equipment be- ing powered to reduce the length of extension cords. for technical questions, please call 1-800-444-3353. SKU 94191 Page 9...
  • Page 10: Control Panel Features

    NEVER run the Engine with the Fuel Tank Cap removed. (See figure d.) 120 Volt Ac Outlets (5): The Generator is equipped with two 3-hole 120 volt AC outlets to power 120 volt tools and equipment. (See figure d.) for technical questions, please call 1-800-444-3353. SKU 94191 Page 10...
  • Page 11 --) 12V DC Terminal on the Generator. IMPORTANT: This Outlet is designed for operating 12 volt DC appliances only. Do not attempt to charge batteries with this Outlet. (See figure d.) for technical questions, please call 1-800-444-3353. SKU 94191 Page 11...
  • Page 12: Pre-Start Instructions

    The Engine MuST be filled with a high quality grade engine oil. If the Engine will be run in temperatures above 32 degrees Fahrenheit, use SAE 30 weight oil. If the for technical questions, please call 1-800-444-3353. SKU 94191 Page 12...
  • Page 13: Operating Instructions

    Engine and Generator before starting the Engine. WARNING! Never fill the Fuel Tank (31) when the Engine is running or hot. Do not smoke when filling the Fuel Tank. for technical questions, please call 1-800-444-3353. SKU 94191 Page 13...
  • Page 14 WARNING! Connect 120V AC appliances, tools, and equipment only to the two 120V AC Outlets (5). Connect 240 AC appliances, tools, and equipment only for technical questions, please call 1-800-444-3353. SKU 94191 Page 14...
  • Page 15 12V DC Outlet (8). (See figure d.) IMPORTANT: If Engine speed or voltage fluctuates with a load below 250 Watts, move the Engine Choke Lever (21A) to the “HAlf-cHOKE” position. (See figure f.) for technical questions, please call 1-800-444-3353. SKU 94191 Page 15...
  • Page 16: Inspection, Maintenance, And Cleaning

    Do not use a garden hose or anything with liquid to clean the Generator. Liquid may enter the cooling air slots and could damage the interior workings of the Generator. for technical questions, please call 1-800-444-3353. SKU 94191 Page 16...
  • Page 17 Separator (20A). To do so, remove the Air Filter Cover (18A). Remove the Air Filter Element. Immerse the Air Filter Element in a mild solvent and squeeze the Element several times to clean. Remove the Element from the solvent and for technical questions, please call 1-800-444-3353. SKU 94191 Page 17...
  • Page 18 All maintenance, service, or repairs not mentioned in this manual must only be performed by a qualified service technician. for technical questions, please call 1-800-444-3353. SKU 94191 Page 18...
  • Page 19: Troubleshooting

    THE BUYER ASSUMES ALL RISKS AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. for technical questions, please call 1-800-444-3353. SKU 94191 Page 19...
  • Page 20 PARTS lIST - GENERATOR for technical questions, please call 1-800-444-3353. SKU 94191 Page 20...
  • Page 21 ASSEMbly dIAGRAM - GENERATOR for technical questions, please call 1-800-444-3353. SKU 94191 Page 21...
  • Page 22: Parts List - Engine

    Oil Scraper Ring Nut (Special 14mm) Piston Pin Starter Ratchet Spring Piston Pin Circlip Starter Rope Starter Starter Handle Gear Starter Case Assembly Fuel Pipe Spiral Spring Spark Plug Wrench Kit for technical questions, please call 1-800-444-3353. SKU 94191 Page 22...
  • Page 23: Assembly Diagram - Engine

    ASSEMbly dIAGRAM - ENGINE for technical questions, please call 1-800-444-3353. SKU 94191 Page 23...
  • Page 24: Limited 1-Year Warranty

    1 yEAR WARRANTy Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and du- rability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of one year from the date of purchase (90 days if used by a professional contractor or if used as rental equipment).
  • Page 25: Service And Maintenance

    Emission control System Warranty - continued Harbor freight Tools Emission control defects Warranty Provisions length of coverage Service and Maintenance HFT warrants to a first retail purchaser and each sub- Component parts which are not scheduled for replace- sequent purchaser that the engine is free from defects...
  • Page 26: Electrical Diagram

    Electrical diagram Please note: All electrical work should be performed by a qualified service technician. REV 07c, 07h for technical questions, please call 1-800-444-3353. SKU 94191 Page 26...

Table of Contents