If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools. for technical questions, please call 1-800-444-3353. SKU 94191 Page 3...
Maintain labels and nameplates on the Generator. These carry important infor- mation. If unreadable or missing, contact Harbor Freight Tools for a replacement. Make sure the Generator is located on a flat, level, sturdy surface capable of supporting the weight of the Generator and any additional tools and equip- ment.
Avoid contact with hot fuel, oil, exhaust fumes, and solid surfaces. Avoid body contact with fuels, oils, and lubricants used in the Generator and Engine. If swallowed, seek medical treatment immediately. Do not induce vomiting for technical questions, please call 1-800-444-3353. SKU 94191 Page 5...
Abc fire extinguishers on electrical fires. unconditioned electrical output can damage sensitive equipment. Do not use to power sensitive electronic equipment without appropriate line conditioner (sold separately). for technical questions, please call 1-800-444-3353. SKU 94191 Page 6...
Page 7
It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. for technical questions, please call 1-800-444-3353. SKU 94191 Page 7...
Connect the end of the Positive Battery Cable (63) to the Battery’s positive minal. Then connect the Negative Battery Cable (64) to the Battery’s negative (–) terminal. (See figure b.) REV 07h for technical questions, please call 1-800-444-3353. SKU 94191 Page 8...
Generator placement should allow four feet of access to all sides for maintenance and for proper air cooling. Place the Generator as close as possible to the electrical tools and equipment be- ing powered to reduce the length of extension cords. for technical questions, please call 1-800-444-3353. SKU 94191 Page 9...
NEVER run the Engine with the Fuel Tank Cap removed. (See figure d.) 120 Volt Ac Outlets (5): The Generator is equipped with two 3-hole 120 volt AC outlets to power 120 volt tools and equipment. (See figure d.) for technical questions, please call 1-800-444-3353. SKU 94191 Page 10...
Page 11
--) 12V DC Terminal on the Generator. IMPORTANT: This Outlet is designed for operating 12 volt DC appliances only. Do not attempt to charge batteries with this Outlet. (See figure d.) for technical questions, please call 1-800-444-3353. SKU 94191 Page 11...
The Engine MuST be filled with a high quality grade engine oil. If the Engine will be run in temperatures above 32 degrees Fahrenheit, use SAE 30 weight oil. If the for technical questions, please call 1-800-444-3353. SKU 94191 Page 12...
Engine and Generator before starting the Engine. WARNING! Never fill the Fuel Tank (31) when the Engine is running or hot. Do not smoke when filling the Fuel Tank. for technical questions, please call 1-800-444-3353. SKU 94191 Page 13...
Page 14
WARNING! Connect 120V AC appliances, tools, and equipment only to the two 120V AC Outlets (5). Connect 240 AC appliances, tools, and equipment only for technical questions, please call 1-800-444-3353. SKU 94191 Page 14...
Page 15
12V DC Outlet (8). (See figure d.) IMPORTANT: If Engine speed or voltage fluctuates with a load below 250 Watts, move the Engine Choke Lever (21A) to the “HAlf-cHOKE” position. (See figure f.) for technical questions, please call 1-800-444-3353. SKU 94191 Page 15...
Do not use a garden hose or anything with liquid to clean the Generator. Liquid may enter the cooling air slots and could damage the interior workings of the Generator. for technical questions, please call 1-800-444-3353. SKU 94191 Page 16...
Page 17
Separator (20A). To do so, remove the Air Filter Cover (18A). Remove the Air Filter Element. Immerse the Air Filter Element in a mild solvent and squeeze the Element several times to clean. Remove the Element from the solvent and for technical questions, please call 1-800-444-3353. SKU 94191 Page 17...
Page 18
All maintenance, service, or repairs not mentioned in this manual must only be performed by a qualified service technician. for technical questions, please call 1-800-444-3353. SKU 94191 Page 18...
THE BUYER ASSUMES ALL RISKS AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. for technical questions, please call 1-800-444-3353. SKU 94191 Page 19...
Page 20
PARTS lIST - GENERATOR for technical questions, please call 1-800-444-3353. SKU 94191 Page 20...
1 yEAR WARRANTy Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and du- rability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of one year from the date of purchase (90 days if used by a professional contractor or if used as rental equipment).
Emission control System Warranty - continued Harbor freight Tools Emission control defects Warranty Provisions length of coverage Service and Maintenance HFT warrants to a first retail purchaser and each sub- Component parts which are not scheduled for replace- sequent purchaser that the engine is free from defects...
Electrical diagram Please note: All electrical work should be performed by a qualified service technician. REV 07c, 07h for technical questions, please call 1-800-444-3353. SKU 94191 Page 26...