IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE
HOMEOWNER
FOR YOUR SAFETY
WARNING: If the information in this manual
is not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
-- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fi re department.
--Installation and service must be performed
by a qualifi ed installer, service agency or
the gas supplier.
This appliance may be installed in an af-
termarket permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certifi ed kit is
250505-36
DIRECT VENT FIREPLACE
INSTALLATION
AND OPERATING
INSTRUCTIONS
ESTATE_H
SERIES H
5055.8.B

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy Estate

  • Page 1 IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER FOR YOUR SAFETY WARNING: If the information in this manual is not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. -- Do not store or use gasoline or other fl...
  • Page 2: Table Of Contents

    CONTENTS CAUTION ......................3 INSTALLATION REQUIREMENTS ............... 4 CHASE INSULATION ................... 5 FRAMING WITHOUT SCREEN DOOR ..............6 FRAMING FOR SCREEN DOOR ................. 7 HEARTH EXTENSION ..................7 TOP OR REAR VENT ................... 8 VENT ADAPTER INSTALLATION ................ 8 VENTING ....................... 9 ROOF TERMINATION VENTING AND VENT RESTRICTOR ......
  • Page 3: Caution

    CAUTION MAINTENANCE FOR YOUR SAFETY - Do not install or operate your Pacifi c Energy Caution: Turn off gas and electrical power supply and allow ample Gas Stove without fi rst reading and understanding this manual. Any time for unit to cool before servicing appliance. It is recommended installation or operational deviation from the following instructions voids that this appliance and venting should be inspected at least once a the Pacifi c Energy Gas Stove Warranty and may prove hazardous.
  • Page 4: Installation Requirements

    National Fuel Gas Code, ANSI Z223.1 -1988 (in the USA), and approved per local codes. Only qualifi ed (licensed or trained) personnel should install this product. The Estate Fireplace is designed to be framed at zero clearance COMBUSTIBLE MANTEL to combustible material with conventional lumber. Ensure framing dimensions are maintained during construction.
  • Page 5: Chase Insulation

    Extended TOP STANDOFFS Standoffs The Estate Fireplace is shipped with the short top standoffs in place and the extended top standoffs loose. If the Optional Screen Door is to be installed, the short standoffs must be replaced with the extended standoffs.
  • Page 6: Framing Without Screen Door

    FRAMING WITHOUT SCREEN DOOR installations, consult local building codes for specifi c requirements. In planning the installation for the Estate Fireplace, it is necessary to Ensure framing dimensions are maintained during construction. determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed.
  • Page 7: Framing For Screen Door

    Fig. #7b CONCRETE BOARD DETAIL In planning the installation for the Estate Fireplace, it is necessary to determine where the unit is to be installed, and where the location of vent system and gas supply piping may be plumbed. Various instal-...
  • Page 8: Top Or Rear Vent

    Fig. # 8b Vent Cover VENT ADAPTER INSTALLATION Plate The Estate fi replace easily adapts to use either the Pacifi c Energy Flex Vent Cover Vent, or the Simpson Dura-Vent GS venting system. Each system Gasket requires a specifi c vent adapter. Use the Pacifi c Flex Vent adapter (ENCD.PEADPT) or the Dura-Vent adapter (ENCD.DVADPT).
  • Page 9: Venting

    Vent system components approved for use with the Estate Fireplace bers to avoid any extra framing. Consult your local building codes are shown in Figure # 9 and Appendix A. The Estate Fireplace is prior to proceeding. The vent kit will accommodate a maximum wall also tested and certifi ed for use with SIMPSON DURA-VENT DIRECT thickness of 11-1/2 inches.
  • Page 10: Roof Termination Venting And Vent Restrictor

    PACIFIC ENERGY ROOF TERMINATION VENTING AND VENT RESTRICTOR Included with the unit is a Vent Restrictor. This item is used for air NOTE: The vent must be a minimum 4' long and must not exceed fl ow regulation when the vent height is 25 ft. or more. Installation of a total length of 40'.
  • Page 11: Vent Connection

    VENT CONNECTION Fig. # 10 Note: This section refers only to Pacifi c Energy fl ex vent. Attaching the venting to the unit before framing begins is preferred. Once the fi replace is in position proceed to attach the venting. (see Fig # 9) The fl exible vent pipe may be stretched to accommodate various lengths of venting.
  • Page 12: Vent Extension

    VENT EXTENSION Fig. # 12 Note: This section refers only to Pacifi c Energy fl ex vent. PIPE SUPPORT Vent Pipe Kits may be combined together for longer vent length. Extend the fl ex pipes as shown in fi gure # 12. Use the 4 and 8 inch couplers supplied with the vent kit.
  • Page 13: Vent Terminal Installation

    VENT TERMINAL INSTALLATION Fig. # 14 Where a vent pipe passes through a combustible wall, a wall thimble must be used to retain insulation and maintain a 1 inch clearance. The wall thimble may be cut to length for various wall thicknesses. (see Fig.
  • Page 14: Roof Vent Terminal Installation

    ROOF VENT TERMINAL INSTALLATION Fig. # 16 Firestops must be used where a vent passes through a fl oor. Where a vent passes through a ceiling, a wall/roof thimble must be used to retain 10 1/2" insulation and maintain a 1 inch clearance. Avoid cutting rafters. 1) Once the terminal location is determined, cut and frame a minimum 10-1/2"...
  • Page 15 Fig. # 17 Fig. # 18 6) Place the storm collar down over the pipe until it is level. Tighten roof vent terminal. Secure to the collar with screws provided. Seal the storm collar for a snug fi t. Apply a thick horizontal ring of mastic joint and screw heads using the high temperature sealant provided.
  • Page 16: Optional Venting

    OPTIONAL VENTING SIMPSON DURA-VENT - DIRECT VENT GS SYSTEM The Estate Fireplace is also tested and certifi ed for use with SIMPSON Follow the vent pipe manufacturer's instructions for assembly and DURA-VENT DIRECT VENT GS pipe. Kits for venting either through installation.
  • Page 17 Fig. # 19c ROOF TERMINATION ROOF TERMINATION TOP VENTING REAR VENTING MAX. DURA-VENT GS DURA-VENT GS NOTE: The roof termina- HORIZONTAL RUN tion vent must not exceed a total length of 40 feet. Any combination of rise and run may be used but must be constrained to the boundaries of this chart.
  • Page 18 Roof Termination Venting To connect the Dura-Vent GS venting system to the To connect the Dura-Vent GS venting system to the Estate Fireplace fl ue outlet, a Dura-Vent Pipe Adaptor Estate Fireplace fl ue outlet, a Dura-Vent Pipe Adaptor is required.
  • Page 19: Optional Snorkel Vent Terminal

    OPTIONAL SNORKEL VENT TERMINAL To connect the Dura-Vent GS Snorkel Termination to the Estate fl exible vent, an Estate Snorkel Adaptor (ESTD.SNADPT) is required. For installations requiring a vertical rise on the exterior of the building, a 14 inch or a 36 inch tall Snorkel Termination is available from Simpson Attach the Estate Snorkel Adaptor to the Snorkel Terminal (see Dura-Vent or your nearest Pacifi c Energy Authorized Dealer.
  • Page 20: Manufactured (Mobile) Home

    MANUFACTURED (MOBILE) HOME Correct gas pressure requirement: In some jurisdictions, the Estate Fireplace may be installed in Manu- factured Homes after the "fi rst sale". Consult local codes for ap- Natural Gas Propane proval. The fi replace must be fastened in place.
  • Page 21: Burner Removal

    BURNER REMOVAL Fig. # 21 Caution: Turn off gas and electrical power supply and allow ample time for the unit to cool before proceeding. The glass frame must be removed, if installed, to remove the burner from the fi rebox. The glass frame is held in place by three over-center latches located under the fi rebox along the front edge.
  • Page 22: Log Set Assembly

    LOG SET ASSEMBLY Fig. # 24 Step 1 Unpack and inspect log set. There should be a total of 7 logs, one Ember Floor Pt# 5097.26105 ember bed and two base brick panels. Gas and vent connections should be completed before installing the log set. Position the logs, ember bed and base bricks as indicated by pictures below.
  • Page 23 Fig. # 26a Fig. # 25 Step 5 Middle Front Log Pt# 5097.23 Step 7 Right Front Chunk Pt# 5097.2614 Step 6 Left Front Log Pt# 5097.25 Step 8 Left Front Chunk Pt# 5097.2613 Fig. # 26b Complete Log Set Placement 250505-36 ESTATE_H...
  • Page 24: Optional Blower

    OPTIONAL BLOWER 115 VOLTS Fig. # 28 60 Hz Electrical Supply: 0.5 AMPERES It is recommended that the fi replace electrical receptacle box be prewired during installation The optional blower (kit # ESTG.BLOWA) ROCKER SNAP DISC SWITCH SWITCH is equipped with a three prong power cord and may be installed and plugged in at a later date.
  • Page 25: Screen Door Installation

    SCREEN DOOR INSTALLATION Unpack and inspect the Screen Door. A fl athead, Phillips, or a #2 WARNING: Non-combustible facing material and extended top stand- Robertson screwdriver is required to install this kit. The Screen Door offs must be used if the Optional Screen Door is to be installed. must be installed before the optional top and bottom louvers.
  • Page 26: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING phone in your building. WARNING: If you do not follow these - Immediately call your gas supplier from a neigh- instructions exactly, a fi re or explosion bour's phone. Follow the gas supplier's instruc- may result causing property damage, tions.
  • Page 27: First Fire

    OPERATION Fig. # 31 The Estate Fireplace comes equipped with a millivolt combination gas valve. An optional wall thermostat may be installed to operate the burner automatically. Once a pilot light has been established, and the gas valve knob turned to the "ON" position, the unit may be operated one of two ways: Fig.
  • Page 28: Replacement Parts

    2....PANEL, RIGHT OR LEFT SIDE .......5098.403 13....FRONT FACING FRAME ......ESTD.1714 3....PANEL, BACK ..........5098.402 14....OPTIONAL BLOWER KIT ....... ESTG.BLOWA ....ESTATE FLOOR PANEL SET .....5098.40041 4....LEFT SIDE FLOOR PANEL ......5098.4002 ....LOG SET, COMPLETE .......5097.26141 5....RIGHT SIDE FLOOR PANEL ......5098.4003 #1....EMBER FLOOR (part of log set) ....5097.26105 6....CENTER FLOOR PANEL ......5098.4004...
  • Page 29: Burner Replacement Parts

    ....THERMOPILE ............5010 18....VALVE TRAY ASSEMBLY ......ESTH.3770 ....THERMOCOUPLE ..........5010.3 19....BURNER SUPPLY TUBE ASSEMBLY ..ESTH.3773 ....PILOT SUPPLY TUBE c/w FITTINGS ...5003.0001 20....ESTATE MANIFOLD ......ESTH.5012502 ....PILOT ORIFICE, NG ..........5009.17 21....MANIFOLD GASKET ........5068.2892 7....BURNER ..............5011.9 22....ORIFICE, 50% NG #45 ........5021.34 8....IGNITER ...............5016.5 23....VALVE COVER PLATE ......MIND.186201...
  • Page 30: Louver Installation Guide

    APPENDIX A Louver Installation Guide Metalic Black ESTD.BKLVR Gold ESTD.GDLVRA Nickel ESTD.NILVRA This kit contains: 1 ..Top Louver 1 ..Bottom Louver 2 ..#8 x 1/2" sheet metal screws Installation Unpack and inspect all parts. A fl athead or a #2 Robertson screwdriver is required Fig.
  • Page 31: Wall Termination Kit

    Wall Termination Kit GASC.WALKIT This vent kit is for use with these models: The ESTATE and The ESTEEM fi replaces. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 1 ..Horizontal Vent Terminal 4 ..
  • Page 32: Roof Termination Kit

    Roof Termination Kit ESTD.ROTKIT This vent kit is for use with these models: The ESTATE and The ESTEEM fi replaces. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 1 ..Roof Vent Terminal...
  • Page 33: 5' Vent Pipe Kit

    5' Vent Pipe Kit ESTD.VP05 This vent kit is for use with these models: The ESTATE and The ESTEEM fi replaces. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 5' ..4" Flex Vent 3 ..
  • Page 34: 10' Vent Pipe Kit

    10' Vent Pipe Kit ESTD.VP10 This vent kit is for use with these models: The ESTATE and The ESTEEM fi replaces. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 1 ....Firestop 10' ....
  • Page 35: Safety Label

    MADE IN CANADA This Appliance is Equipped For Use With / FABRIQUE AU CANADA Cet Appareil est Équipé Pour Utilise Avec : MODEL/ SERIES/ NATURAL GAS LP-GAS THE ESTATE MODELE: SERIE: GAZ NATUREL LP GAZ FOR USE WITH/ NATURAL GAS/ LP GAS/ EN CASE D’EMPLOI AVEC:...
  • Page 36 Pacifi c Energy Fireplace Products Ltd. www.pacifi cenergy.net 2975 Allenby Rd., Duncan, B.C. V9L 4T8 Phone: 250-748-1184 Printed in Canada...