IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE
HOMEOWNER
FOR YOUR SAFETY
WARNING:
If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
-- Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
f i r e - p a r t s . c o m
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
--Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
This appliance may be installed in an
aftermarket
permanently
manufactured (mobile) home, where not
prohibited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certified kit is
used.
220403-36
located,
ESTATE_G
SERIES G
DIRECT VENT FIREPLACE
INSTALLATION
AND OPERATING
INSTRUCTIONS
5055.8.A
1

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy G Series

  • Page 1 IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER FOR YOUR SAFETY WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. -- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    CONTENTS CAUTION ......................3 INSTALLATION REQUIREMENTS ..............4 CHASE INSULATION ..................5 FRAMING WITHOUT SCREEN FRONT ............. 6 FRAMING FOR SCREEN FRONT ..............7 HEARTH EXTENSION ..................7 TOP OR REAR VENT ..................8 VENT ADAPTER INSTALLATION ..............8 VENTING ......................9 ROOF TERMINATION VENTING AND VENT RESTRICTOR ......
  • Page 3: Caution

    Replacement glass can be obtained from your nearest for a couple of hours. This is due to the curing of paints, sealants and Pacific Energy dealer. The size required is 31 1/4" x 19" x 5mm. Use lubricants used in the manufacturing process. This condition is ceramic glass only.
  • Page 4: Installation Requirements

    Mantel support (3 1/2" wide max.) ..0 in. (0 mm) 9 1/4" (235 mm) 14" (356 mm) Pacific Energy Vent pipe ..... 1 in. (25 mm) f i r e - p a r t s . c o m 6 5/8" (168 mm) 11"...
  • Page 5: Chase Insulation

    Fig. # 3a MANTEL CLEARANCES WITH OPTIONAL SCREEN FRONT FINISHED WALL COMBUSTIBLE TOP OR MANTEL REAR VENTING 1" [25mm.] EXTENDED 8" HIGH STANDOFF CEMENT BOARD f i r e - p a r t s . c o m MANDATORY WITH HEADER SCREEN DOORS Ref.
  • Page 6: Framing Without Screen Front

    FRAMING WITHOUT SCREEN FRONT In planning the installation for the Estate Fireplace, it is necessary to installations, consult local building codes for specific requirements. determine where the unit is to be installed, location of vent system and Ensure framing dimensions are maintained during construction. where gas supply piping may be plumbed.
  • Page 7: Framing For Screen Front

    FRAMING FOR SCREEN FRONT Fig. #7b CONCRETE BOARD DETAIL In planning the installation for the Estate Fireplace, it is necessary to determine where the unit is to be installed, and where the location of vent system and gas supply piping may be plumbed. Various Extended installations are possible, such as, into an existing wall, a corner, a...
  • Page 8: Top Or Rear Vent

    Fig. # 8b Vent Cover VENT ADAPTER INSTALLATION Plate The Estate fireplace easily adapts to use either the Pacific Energy Vent Cover Flex Vent, or the Simpson Dura-Vent GS venting system. Each Gasket system requires a specific vent adapter. Use the Pacific Flex Vent adapter (ENCD.PEADPT) or the Dura-Vent adapter (ENCD.DVADPT).
  • Page 9: Venting

    MATERIAL BE CLOSER THAN 1 INCH FROM THE VERTICAL selected. AND HORIZONTAL SECTIONS OF THE PACIFIC ENERGY VENT Use only Pacific Energy vent kits #: SYSTEM OR 1-3/4 INCHES FROM THE SIMPSON DURA-VENT GASC.WALKIT - Wall Termination Kit...
  • Page 10: Roof Termination Venting And Vent Restrictor

    PACIFIC ENERGY ROOF TERMINATION VENTING AND VENT RESTRICTOR Included with the unit is a Vent Restrictor. This item is NOTE: The vent must be a minimum 4' long and used for air flow regulation when the vent height is 25 ft.
  • Page 11: Vent Connection

    VENT CONNECTION Fig. # 10 Note: This section refers only to Pacific Energy flex vent. Attaching the venting to the unit before framing begins is preferred. Once the fireplace is in position proceed to attach the venting. (see Fig # 9) The flexible vent pipe may be stretched to accommo- date various lengths of venting.
  • Page 12: Vent Extension

    VENT EXTENSION Fig. # 12 Note: This section refers only to Pacific Energy flex vent. PIPE SUPPORT Vent Pipe Kits may be combined together for longer vent length. Extend the flex pipes as shown in figure # 12. Use the 4 and 8 inch couplers supplied with the vent kit.
  • Page 13: Vent Terminal Installation

    VENT TERMINAL INSTALLATION Fig. # 14 Where a vent pipe passes through a combustible wall, a wall thimble must be used to retain insulation and maintain a 1 inch clearance. The wall thimble may be cut to length for various wall thicknesses. (see Fig.
  • Page 14: Roof Vent Terminal Installation

    ROOF VENT TERMINAL INSTALLATION Fig. # 16 Firestops must be used where a vent passes through a floor. Where a vent passes through a ceiling, a wall/roof thimble must be used to retain insulation and maintain a 1 inch clearance. Avoid cutting rafters.
  • Page 15 Fig. # 17 Fig. # 18 6) Place the storm collar down over the pipe until it is level. Tighten vent terminal. Secure to the collar with screws provided. Seal the joint storm collar for a snug fit. Apply a thick horizontal ring of mastic and screw heads using the high temperature sealant provided.
  • Page 16: Optional Venting

    For Vent Restrictor installation, refer to the Pacific Energy Roof Termination Venting and Vent Restrictor section (see Fig. #8f & 23). CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE...
  • Page 17 Fig. # 19c ROOF TERMINATION ROOF TERMINATION TOP VENTING REAR VENTING DURA-VENT GS DURA-VENT GS NOTE: The roof termi- HORIZONTAL RUN nation vent must not ex- ceed a total length of 40 1’ 2’ 3’ 4’ 5’ feet. Any combination of rise and run may be used but must be constrained 5’...
  • Page 18 Fig. # 19e Venting System Components Dura-Vent GS Catalog # galv. black 6" pipe length 908B 9" pipe length 907B 12" pipe length 906B 24" pipe length 904B 36" pipe length 903B 48" pipe length 902B 11" - 14 5/8" adjustable pipe length 911B 90°...
  • Page 19: Optional Snorkel Vent Terminal

    14 inch or a 36 inch tall Snorkel Termination is available from Attach the Estate Snorkel Adaptor to the Snorkel Terminal (see Simpson Dura-Vent or your nearest Pacific Energy Authorized Dealer. Fig. #19g). Extend both the 8-inch outer and the 4-inch inner flex pipe Follow the same installation procedures as for standard Wall Termi- through the wall thimble.
  • Page 20: Manufactured (Mobile) Home

    MANUFACTURED (MOBILE) HOME Correct gas pressure requirement: In some jurisdictions, the Estate Fireplace may be installed in Manu- factured Homes after the "first sale". Consult local codes for Natural Gas Propane approval. The fireplace must be fastened in place. Min. Pressure 5.0"...
  • Page 21: Burner Removal

    BURNER REMOVAL Fig. # 21 Caution: Turn off gas and electrical power supply and allow ample time for the unit to cool before proceeding. The glass frame must be removed, if installed, to remove the burner from the firebox. The glass frame is held in place by three over-center latches located under the firebox along the front edge.
  • Page 22: Ember Material Installation

    EMBER MATERIAL INSTALLATION Two different types of ember material are supplied Place the Glowing Embers randomly on the burner with this fireplace, Platinum Bright Embers and area away from the burner ports. This will produce Glowing Embers. The Platinum Bright Embers the best results.
  • Page 23: Log Set Assembly

    LOG SET ASSEMBLY Step 3 Fig. # 25 Right Rear Log Placement Unpack and inspect the log set. There should be a total of six logs, and one coal chunk. All gas and vent connections should be made before installing the log set.
  • Page 24: Optional Blower

    OPTIONAL BLOWER 115 VOLTS Fig. # 29 60 Hz Electrical Supply: 0.5 AMPERES It is recommended that the fireplace electrical receptacle box be prewired during installation The optional blower (kit # ESTG.BLOWA) ROCKER SNAP DISC SWITCH SWITCH is equipped with a three prong power cord and may be installed and plugged in at a later date.
  • Page 25: Screen Door Installation

    SCREEN DOOR INSTALLATION WARNING: Non-combustible facing material and extended top Unpack and inspect the Screen Door. A flathead, Phillips, or a #2 standoffs must be used if the Optional Screen Door is to be installed. Robertson screwdriver is required to install this kit. The Screen Door must be installed before the optional top and bottom louvers.
  • Page 26: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING phone in your building. WARNING: If you do not follow these - Immediately call your gas supplier from a neigh- instructions exactly, a fire or explosion bour's phone. Follow the gas supplier's instruc- may result causing property damage, tions.
  • Page 27: First Fire

    FIRST FIRE FLAME ADJUSTMENT When lit for the first time, the appliance will emit a slight odour for a The air shutter on the burner venturi tube controls the primary couple of hours. This is due to the curing of paints, sealants and combustion air to the gas burner.
  • Page 28: Replacement Parts

    10 ..LOUVER, TOP ASSEMBLY ....ESTD.1719_ _ All parts may be ordered from your nearest Pacific Energy Gas Stove dealer. Contact Pacific Energy for the location of the dealer nearest you. When ordering Overlays and Louvers, please specify the appropriate finish code. Codes are as follows: Porcelain Finish Black .........
  • Page 29: Burner Replacement Parts

    10 ..BURNER PAN ASSEMBLY ......ESTF.3705 ....EMBERS, BRIGHT PLATINUM (not shown) ..5096.98 ....EMBERS, GLOWING (not shown) ..EMBR.506862 All parts may be ordered from your nearest Pacific Energy Gas Stove dealer. Contact Pacific Energy for the location of the dealer nearest you.
  • Page 30: Louver Installation Guide

    APPENDIX A Louver Installation Guide Metalic Black ESTD.BKLVR Gold ESTD.GDLVRA Nickel ESTD.NILVRA This kit contains: 1 ..Top Louver 1 ..Bottom Louver f i r e - p a r t s . c o m 6 ..#8 x 1/2" sheet metal screws Installation Unpack and inspect all parts.
  • Page 31: Wall Termination Kit

    Wall Termination Kit GASC.WALKIT This vent kit is for use with these models: The ESTATE and The ESTEEM fireplaces. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 1 ..Horizontal Vent Terminal 4 ..
  • Page 32: Roof Termination Kit

    Roof Termination Kit ESTD.ROTKIT This vent kit is for use with these models: The ESTATE and The ESTEEM fireplaces. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 1 ..Roof Vent Terminal 3 ..
  • Page 33: 5' Vent Pipe Kit

    5' Vent Pipe Kit ESTD.VP05 This vent kit is for use with these models: The ESTATE and The ESTEEM fireplaces. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 5' ..4" Flex Vent 3 ..
  • Page 34: 10' Vent Pipe Kit

    10' Vent Pipe Kit ESTD.VP10 This vent kit is for use with these models: The ESTATE and The ESTEEM fireplaces. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 10' ... 4" Flex Vent 1 ....
  • Page 35: Safety Label

    / Supports du manteau (Max. 3 1/2 po. Extension) 0 in./ 0 po. (0 mm) Pacific Energy Flex Pipe system / le système Conduit Flexible de Pacific Energy 1 in./ 1 po. (25 mm) Dura-Vent GS or Secure Vent system / le système Dura-Vent GS ou Secure Vent 1 3/4 in./ 1 3/4 po.
  • Page 36 - p a r t s . c o m Pacific Energy Fireplace Products Ltd. PO Box 1060, Duncan, B.C. V9L 3Y2 Phone: 250-748-1184 Web site: www.pacificenergy.net Printed in Canada...

This manual is also suitable for:

Estate

Table of Contents