Pacific energy Esprit Installation And Operating Instructions Manual

Pacific energy Esprit Installation And Operating Instructions Manual

Zero clearance fireplace

Advertisement

Quick Links

INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: If the information in these instruc-
tions is not followed exactly a fire or explosion
may result causing property damage, personal
injury or death.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical Switch.
• Do not use any phone in your building.
• Immediately call your gas supplier
• from a neighbour's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier
call the fire department.
Do not store or use gasoline or other
flammable vapours and liquids in the
vicinity of this or any other appliance.
This appliance is suitable for installation in a
bedroom or bed sitting room.
This appliance may be installed in an after-
market permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appli-
ance is not convertible for use with other
gases unless a certified kit is used.
Visit www. pacificenergy.net for the most recent version of this manual
280617-40
ESPRIT
INSTALLATION
AND OPERATING
INSTRUCTIONS
MODEL: ESPR.BODYB
ESPRIT ZERO CLEARANCE
FIREPLACE
ESPRIT
SERIAL #
5056.201-A

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy Esprit

  • Page 1 This appli- MODEL: ESPR.BODYB ance is not convertible for use with other gases unless a certified kit is used. ESPRIT ZERO CLEARANCE FIREPLACE Visit www. pacificenergy.net for the most recent version of this manual 5056.201-A...
  • Page 2: Table Of Contents

    Glass Burner Kit Installation / Removal ....32 Key Lock..............12 Intake Air Damper Installation ......33 Warnings and Cautions .........12 Replacement Parts ..........34 Wiring Diagram ............35 Maintenance ............13 Rating Label ............36 Glass Door ............13 Annual Inspection ..........13 Periodically ............13 280617-40 ESPRIT 5056.201-A...
  • Page 3: Important Note For The Commonwealth Of Massachusetts

    A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. ESPRIT 280617-40...
  • Page 4: Caution

    Caution FOR YOUR SAFETY - Do not install or operate your Pacific Energy fireplace without first reading and understanding this manual. Any installation or operational deviation from the following instruc- tions voids the Pacific Energy Warranty and may prove hazardous.
  • Page 5: Safety

    • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier call the fire department. • Installation and service must be performed by a qualified installer, service agency or the gas supplier. ESPRIT 280617-40 5056.201-A...
  • Page 6: First Fire

    Congratulations on your purchase of a Pacific Energy Gas Appliance. Your fireplace has been professionally installed by: Dealer name: ___________________________________________________ Phone Number:___________________________________________________ If you discover any problems with your gas appliance contact your dealer immediately to have the unit repaired.
  • Page 7: Remote Control Operation

    UP/DOWN Arrow Key MODE Key Figure 1: Proflame 2 handset. TRANSMISSION KEY LOCK LOW BATTERY ALARM THERMOSTAT OFF/ ON/SMART ROOM TEMPERATURE SMART CPI MODE SET POINT: TEMPERATURE/LEVEL/STATE FLAME LEVEL COMFORT FAN Figure 2: Proflame 2 LCD display. ESPRIT 280617-40 5056.201-A...
  • Page 8: Ifc Module

    5. On the remote transmitter, push the power on button once. The remote transmitter will beep 4 times to indicate that the remote transmitter and the control module are now synchronized. The remote transmitter is now ready to use. Figure 5: On-off switch cover. Figure 4: On-off switch. Figure 3: IFC module. 280617-40 ESPRIT 5056.201-A...
  • Page 9: Temperature Indication Display

    Figure 8: Key lock. To activate this function, press the MODE and UP keys at the same time. The lock icon will appear (Figure 8). To de-activate this function, press the MODE and UP keys at the same time. ESPRIT 280617-40 5056.201-A...
  • Page 10: Remote Flame Control

    (Figure 11). To adjust the set point, press the up or down arrow keys until the desi red set point temperature is displayed on the LCD screen of the remote transmitter (Figure 12). Figure 12: Smart flame function set low. 280617-40 ESPRIT 5056.201-A...
  • Page 11: Comfort Fan Speed Control

    (fig.14). Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode (CPI). Pressing the Down Arrow Key will return to IPI. A single “beep” will confirm the reception of the command. Figure 14: IPI CPI Selection. ESPRIT 280617-40 5056.201-A...
  • Page 12: Low Battery Detection

    Shock Hazard. Can cause severe injury or death This device is powered by line voltage. Do not try to repair this device. In no way is the enclosure to be tampered with or opened. Disconnect from line voltage before perform- ing any maintenance. 280617-40 ESPRIT 5056.201-A...
  • Page 13: Maintenance

    Replacement door can be obtained from your nearest Pacific Energy dealer. Do not substitute with any other type. To remove broken glass, remove Door as noted in “Door Removal” section.
  • Page 14: Lighting Instructions

    Lighting Instructions 280617-40 ESPRIT 5056.201-A...
  • Page 15: Fireplace Dimensions

    482 mm 10” 254 mm 32” 15 3/4” 813 mm 400 mm 34 5/16” 871 mm 40 1/8” 1020 mm Figure 18: Esprit dimensions. 43 3/8” 1101 mm Non-combustible 48” 1219 mm 24” 610 mm 33 5/8” 854 mm Combustible 1 1/8”...
  • Page 16 48” 1220 mm Combustible 24” 610 mm 33 5/8” 854 mm Combustible 1 1/8” 29 mm Minimum Figure 20: Framing at the corner. Figure 21: Minimum clearance corner framing. 280617-40 ESPRIT 5056.201-A...
  • Page 17: Clearances To Combustibles

    When the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Specified clearances shall be maintained from the top surface of carpeting, tile, etc. ESPRIT 280617-40 5056.201-A...
  • Page 18: Locating The Fireplace

    Due to high temperatures, do not locate this fireplace in areas of high traffic or near furniture or draperies. For places where a second side wall is specified, fireplace should be accessible for service Figure 24: Common installation options. 33 5/8” 854mm 45” 1143mm Figure 25: Framing dimensions. 280617-40 ESPRIT 5056.201-A...
  • Page 19: Surround Installation Instructions

    2. Install screen with the frame in slots on inner side of the surround base. 3. Install the surround front by positioning it so as to clear the notches and secure by applying downward pressure in order to engage the locking tabs. Louvered Surround Clean face Surround Figure 28: Surround dimensions. ESPRIT 280617-40 5056.201-A...
  • Page 20 42 1/4” 1 5/8” 1067 mm 41 mm 20 7/8” 22 1/2” 530 mm 559 mm 39 1/2” 990 mm Figure 29: Esprit straight edge surround dimensions. 280617-40 ESPRIT 5056.201-A...
  • Page 21: Venting

    Venting ESPRIT LINEAR FIREPLACE VENTING CHART NO VENTING OPTION VENTING ENVELOPE NO VENTING OPTION VENTING HORIZONTAL RUN Note: The intake damper positions specified in this chart were set in a controlled testing environ- ment, and serve as a general guideline for installations. Every venting configuration is different, and the damper setting may need slight adjustment from this chart.
  • Page 22: Vent Terminal Minimum Clearances

    * for U.S.A. Installations follow the current National Fuel Gas Code, ANSI Z223.1 This fireplace is certified for use with 4” x 6-5/8”coaxial venting components only. It is permitted to only use certified venting for this appliance. 280617-40 ESPRIT 5056.201-A...
  • Page 23: Venting Components

    Venting Components NOTE: Mixing venting components from different manufacturers is inadvisable. Figure 30: 4”x 6-five eights” Rigid Piping Cross Reference Chart. Figure 31: 4”x6-five eigths” Rigid Pipe Components Cross Reference Chart. ESPRIT 280617-40 5056.201-A...
  • Page 24: Plumbing And Electrical

    Figure 33: Electrical connection. Electrical connection Open the access panel as seen in Figure 33 and connect the line wires to the supplied wires inside the junction box using marrettes. A licensed electrician must be used to make this connection. 280617-40 ESPRIT 5056.201-A...
  • Page 25: Gas Supply

    30,000 btu/hr max. 22,000 btu/hr min. Input Pressure Natural Gas Propane Minimum 5.0” WC 11.0” WC 1.52mm 26,000 btu/hr max. Maximum 13.9” WC 13.9” WC 22,000 btu/hr min. Manifold Pressure High 3.5” WC 10” WC 1.6” WC 6.4” WC ESPRIT 280617-40 5056.201-A...
  • Page 26: Gas Pressure Testing Procedure

    Venturi adjustment screw Figure 34: Gas valve location. PILOT ADJUSTMENT PILOT MAIN GAS SCREW SOLENOID SOLENOID PRESSURE MANIFOLD PRESSURE INLET MODULATOR TEST POINT PRESSURE DEVICE TEST POINT Figure 35: Gas control valve. 280617-40 ESPRIT 5056.201-A...
  • Page 27: Propane Conversion

    The correct venturi settings are shown in Figure 38. Loosen the screw and slide the shutter. Tighten the screw, and return the burner into position. Figure 38: Venturi shutter. ESPRIT 280617-40 5056.201-A...
  • Page 28: Door Installation/Removal

    4. Remove baffle, rear panel and side panels. 5. Remove burner tray together with valve assembly. Figure 40: Fan installation and removal. 6. Disconnect fan electrical wires and remove fan fasteners. 7. Remove fan out of the firebox assembly. 280617-40 ESPRIT 5056.201-A...
  • Page 29: Fan Removal Before Fireplace Installation

    Figure 44. 5. Do panel removal in reverse order. Figure 42: Back panel. Baf e Side panel Figure 43: Side panel. Figure 44: Baffle mounts. ESPRIT 280617-40 5056.201-A...
  • Page 30: Burner And Tray Installation / Removal

    Embers Placement Place embers chunks in rock tray as seen in Figure 47. Do not block air openings and pilot elements with embers. Figure 47: Ember placement. Pilot Air opening Figure 48: Pilot and air opening. 280617-40 ESPRIT 5056.201-A...
  • Page 31: Log Set Installation / Removal

    Figure 51: Rear log number 3. Figure 50: Rear logs 1 and 2. Figure 52: Left side log number 6. Figure 53: Front logs numbers 4 and 5. Figure 55: Completed log set up. Figure 54: Center log number 7. ESPRIT 280617-40 5056.201-A...
  • Page 32: Glass Burner Kit Installation / Removal

    To install the optional rock set, simply place desired number of rocks into the fireplace pan as seen in Figure 57 making sure no rocks are in the flame when the unit is operating. Figure 56: Glass media installation. Figure 57: Rock set installation. 280617-40 ESPRIT 5056.201-A...
  • Page 33: Intake Air Damper Installation

    Intake Air Damper Installation The Esprit fireplaces come with the damper that can limit the flow of intake air. This damper is located behind the air baffle at the top of the inner firebox. Sometimes on installations that involve vertical venting configurations over 23 feet in height, the intake air tends to accelerate down the vent causing hectic flame action.
  • Page 34: Replacement Parts

    UNIT PART ESPRIT LINEAR GAS FIREPLACE ........ESPR.BODYA ........1203003 REPLACEMENT PARTS ESPRIT REPLACEMENT DOOR WITH GLASS ......PERP.3008 ......... 8000.0867 ESPRIT REPLACEMENT SCREEN ........ESPR.SCRNA .........8000.0164 COMPLETE REPLACEMENT GAS TRAY ......... PERP.3004 .........8000.0864 REPLACEMENT GAS VALVE ..........GASC.VALVEA .........8000.0194 REPLACEMENT CONTROL MODULE ......... GASC.MODA .........8000.0192 REPLACEMENT PILOT ASSEMBLY........
  • Page 35: Wiring Diagram

    Wiring Diagram LAMP COMFORT Diagnostics Interface Caution: Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and danger- ous operation. Verify proper operation after servicing. ESPRIT 280617-40 5056.201-A...
  • Page 36: Rating Label

    Manifold pressure / Pression de la tuyauterie: Maximum 3.5 in/wc / 3.5 po/c.e. 10.0 in/wc / 11.0 po/c.e. MODEL/ MODELE: (.87 kPa) (2.74 kPa) ESPRIT Orifice Size / Diametre de l’injectuer: 2.55mm 1.52mm SERIES/ SERIE: Input BTU/hr (kW) / Entree BTU/h (kW): Max.:30,000Btu (8.8kw)
  • Page 37 ESPRIT 280617-40 5056.201-A...
  • Page 38 280617-40 ESPRIT 5056.201-A...
  • Page 39 ESPRIT 280617-40 5056.201-A...
  • Page 40 © 2017 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copy- right laws. For technical support, please contact your retailer Web site: www.pacificenergy.net 2975 Allenby Rd., Duncan,...