Pacific energy Estate A Series Installation And Operating Instructions Manual
Pacific energy Estate A Series Installation And Operating Instructions Manual

Pacific energy Estate A Series Installation And Operating Instructions Manual

Direct vent fireplace

Advertisement

IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE
HOMEOWNER
FOR YOUR SAFETY
WARNING:
If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
-- Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
f i r e - p a r t s . c o m
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
--Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
This appliance may be installed in an
aftermarket
permanently
manufactured (mobile) home, where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
061098-36
located,
AND OPERATING
ESTATE_A
SERIES A
DIRECT VENT FIREPLACE
INSTALLATION
INSTRUCTIONS
5055.8
1

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy Estate A Series

  • Page 1 IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER FOR YOUR SAFETY WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. -- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    Contents CAUTION ......................3 SAFETY ......................3 MAINTENANCE ....................3 INSTALLATION REQUIREMENTS ..............4 FRAMING ......................5 VENTING ......................6 VENT CONNECTION ..................9 VENT EXTENSION ....................10 VENT TERMINAL INSTALLATION..............11 ROOF VENT TERMINAL INSTALLATION ............12 OPTIONAL VENTING ..................14 OPTIONAL SNORKEL VENT TERMINAL ............16 MANUFACTURED (MOBILE) HOME ..............17 GAS SUPPLY .....................17 WALL SWITCH OR THERMOSTAT ..............17...
  • Page 3: Caution

    CAUTION MAINTENANCE FOR YOUR SAFETY - Do not install or operate your Pacific Energy Caution: Turn off gas and electrical power supply and allow ample Gas Stove without first reading and understanding this manual. Any time for unit to cool before servicing appliance. It is recommended...
  • Page 4: Installation Requirements

    (305 mm) With Mantel Shield ......See Figure # 3 Mantel support (3 1/2" wide max.) ..0 in. (0 mm) Ref. Mantel Width Ref. Clearance Pacific Energy Vent pipe ..... 1 in. (25 mm) 12" (305 mm) 17" (432 mm) Simpson Dura-Vent GS pipe ..
  • Page 5: Framing

    FRAMING system is installed. Heavier construction may be required for some installations, consult local building codes for specific requirements. Ensure framing dimensions are maintained during construction. In planning the installation for the Estate Fireplace, it is necessary to Bend out the two nailing tabs on each side and secure the fireplace determine where the unit is to be installed, location of vent system and to framing with screws or nails.
  • Page 6: Venting

    MATERIAL BE CLOSER THAN 1 INCH FROM THE VERTICAL Before installing venting for this unit, the installer should read these AND HORIZONTAL SECTIONS OF THE PACIFIC ENERGY VENT instructions to insure that the proper vent configuration has been SYSTEM AND 1-3/4 INCHES FROM THE SIMPSON DURA-VENT selected.
  • Page 7 Fig. # 8b PACIFIC ENERGY ROOF TERMINATION VENTING f i r e - p a r t s . c o m HORIZONTAL RUN NOTE: The vent must be a minimum 4' long and must not exceed a total length of 40'. Any combination of rise and run may be used but must be constrained to the bounda- ries of this chart.
  • Page 8 Fig. # 9 Horizontal Vent Terminal Pipe Support Set Roof Vent Terminal Pipe Spacer Support Sleeve 4" Vent Connector f i r e - p a r t s . c o m Storm Collar 8" Vent Connector Flashing Firestop Wall / Roof Thimble 4"...
  • Page 9: Vent Connection

    VENT CONNECTION Fig. # 11 It is preferred to attach venting before framing begins. Once the fireplace is in position proceed to attach the venting. (see Fig # 10) The flexible vent pipe may be stretched to accommodate various lengths of venting. Stretch and/or cut to length as required. The 4 inch flexible inner pipe must be centred inside the 8 inch pipe with pipe spacers provided.
  • Page 10: Vent Extension

    VENT EXTENSION Fig. # 13 Vent Pipe Kits may be combined together for longer vent length. PIPE SUPPORT Extend the flex pipes as shown in figure # 13. Use the 4 and 8 inch couplers supplied with the vent kit. Insert coupler into the appropriate flex pipe and secure in place with screws provided.
  • Page 11: Vent Terminal Installation

    VENT TERMINAL INSTALLATION Fig. # 15 Where a vent pipe passes through a combustible wall, a wall thimble must be used to retain insulation and maintain a 1 inch clearance. The wall thimble may be cut to length for various wall thicknesses. (see Fig.
  • Page 12: Roof Vent Terminal Installation

    ROOF VENT TERMINAL INSTALLATION Fig. # 17 Firestops must be used where a vent passes through a floor. Where a vent passes through a ceiling, a wall/roof thimble must be used to retain insulation and maintain a 1 inch clearance. Avoid cutting rafters.
  • Page 13 Fig. # 18 Fig. # 20 6) Place the storm collar down over the pipe until it is level. Tighten vent terminal. Secure to the collar with screws provided. Seal the joint storm collar for a snug fit. Apply a thick horizontal ring of mastic and screw heads using the high temperature sealant provided.
  • Page 14: Optional Venting

    DURA-VENT DIRECT VENT GS pipe. Kits for venting either through the side wall or vertically through the roof are available from Simpson Dura-Vent or your nearest Pacific Energy Authorized Dealer. Before installing the Dura-Vent system, the installer should read the instructions that accompany this appliance to insure proper installa- tion requirements are maintained.
  • Page 15 Fig. # 20c Venting System Components Dura-Vent GS Catalog # galv. black 6" pipe length 908B 9" pipe length 907B 12" pipe length 906B 24" pipe length 904B 36" pipe length 903B 48" pipe length 902B 11" - 14 5/8" adjustable pipe length 911B 90°...
  • Page 16: Optional Snorkel Vent Terminal

    14 inch or a 36 inch tall Snorkel Termination is available from Attach the Estate Snorkel Adaptor to the Snorkel Terminal. Simpson Dura-Vent or your nearest Pacific Energy Authorized Dealer. Extend both the 8-inch outer and the 4-inch inner flex pipe through the wall thimble.
  • Page 17: Manufactured (Mobile) Home

    MANUFACTURED (MOBILE) HOME Correct gas pressure requirement: In some jurisdictions, the Estate Fireplace may be installed in Manufactured Homes after the "first sale". Consult local codes for Natural Gas Propane approval. The fireplace must be fastened in place. Min. Pressure 5.0"...
  • Page 18: Burner Installation

    BURNER INSTALLATION Fig. # 23 The glass frame and window trim overlay must be removed to install the burner into the firebox. The glass frame is held in place by two over-center latches located under the firebox. Fold down the front bottom louver, if installed, to access the screw retaining the window trim overlay.
  • Page 19: Log Set Assembly

    LOG SET ASSEMBLY Step 1 Fig. # 25 Back Log Placement Unpack and inspect log set. There should be a total of 4 logs as shown in Fig. # 24. All gas and vent connections should be made before installing log set. See figure # 25.
  • Page 20: Glowing Embers

    Fig. # 26 FRONT LOG BRACKET EMBERS f i r e - p a r t s . c o m GLOWING EMBERS Note: Only use embers supplied with this appliance. Use of any other materials or incorrectly placed embers may cause an incorrect flame Note: The use of glowing embers is optional.
  • Page 21: Optional Blower

    OPTIONAL BLOWER 115 VOLTS Fig. # 29 60 Hz Electrical Supply: 0.5 AMPERES It is recommended that the fireplace electrical receptacle box be prewired during installation The optional blower (kit # ESTD.BLOB) ROCKER SNAP DISC SWITCH SWITCH is equipped with a three prong power cord and may be installed and plugged in at a later date.
  • Page 22 FOR YOUR SAFETY READ BEFORE LIGHTING phone in your building. WARNING: If you do not follow these - Immediately call your gas supplier from a neigh- instructions exactly, a fire or explosion bour's phone. Follow the gas supplier's instruc- may result causing property damage, tions.
  • Page 23: First Fire

    FIRST FIRE FLAME ADJUSTMENT When lit for the first time, the appliance will emit a slight odour for a The air shutter on the burner venturi tube controls the primary couple of hours. This is due to the curing of paints, sealants and combustion air to the gas burner.
  • Page 24: Replacement Parts

    Radiant, Polished Brass ..... ESTD.ROBRA All parts may be ordered from your nearest Pacific Energy Gas Stove dealer. Contact Pacific Energy for the location of the dealer nearest you. When ordering Overlays and Louvers, please specify the appropriate finish code. Codes are as follows: f i r e - p a r t s .
  • Page 25 f i r e - p a r t s . c o m...
  • Page 26: Louver Installation Guide

    APPENDIX A Louver Installation Guide Metalic Black ESTD.BKLVR Brass ESTD.BRLVR Black ESTD.PBKLVR Blue ESTD.PBELVR Green ESTD.PGNLVR Ivory ESTD.PIYLVR ESTD.PRDLVR This kit contains: 1 ..Top Louver 1 ..Bottom Louver f i r e - p a r t s . c o m 6 ..#8 x 1/2"...
  • Page 27: Overlay Trim Installation Guide

    Overlay Trim Installation Guide This kit contains: 1 ..Standard Overlay Metallic Black ESTD.STDO 1 ..Radiant Overlay Porcelain Enamel Black ESTD.ROPBK Blue ESTD.ROPBE f i r e - p a r t s . c o m Green ESTD.ROPGN Ivory ESTD.ROPIY ESTD.ROPRD Metallic Black ESTD.ROMBK...
  • Page 28: Optional Front Facing Trim Installation Guide

    Optional Front Facing Trim Installation Guide This Installation Guide covers the following kits: Metallic Black ESTD.FTMBK Porcelain Enamel Black ESTD.FTPBK Polished Brass ESTD.ROBRA Blue ESTD.FTPBE Green ESTD.FTPG Ivory ESTD.FTPIY ESTD.FTPRD This kit contains: Metallic Black or Polished Brass finish 1 ..Top Panel f i r e - p a r t s .
  • Page 29 Installation Spring nut Fig. # 1 Unpack and inspect all parts. A flathead or a #2 Robertson screwdriver is required to install this kit. The facing trim kit must be installed before installing the top and bottom louvers. If the louvers are not installed, proceed to step 3.
  • Page 30: Mantel Shield Installation Guide

    Mantel Shield Installation Guide This kit contains: 1 ..Estate Mantel Shield Metallic Black Finish ESTD.MSMBK Porcelain Enamel Finish Black ESTD.MSPBK Blue ESTD.MSPBE Green ESTD.MSPGN Ivory ESTD.MSPIY ESTD.MSPRD 2 ..#8 x 1/2" sheet metal screws f i r e - p a r t s . c o m 2 ..Fibre washer Installation Fig.
  • Page 31: Wall Termination Kit

    Wall Termination Kit GASC.WALKIT This vent kit is for use with model The ESTATE and PACIFIC ENCORE, series A fireplace only. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 1 ..Horizontal Vent Terminal 4 ..
  • Page 32: Roof Termination Kit

    Roof Termination Kit ESTD.ROTKIT This vent kit is for use with model The ESTATE and PACIFIC ENCORE, series A fireplace only. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 1 ..Roof Vent Terminal 3 ..
  • Page 33: 5' Vent Pipe Kit

    5' Vent Pipe Kit ESTD.VP05 This vent kit is for use with model The ESTATE, series A fireplace only. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 5' ..4" Flex Vent 3 ..
  • Page 34: 10' Vent Pipe Kit

    10' Vent Pipe Kit ESTD.VP10 This vent kit is for use with the model ESTATE, Series A fireplace only. Please refer to the Installation Instructions provided with the appliance for proper venting installation. This box contains: 10' ... 4" Flex Vent 1 ....
  • Page 35: Safety Label

    Safety Label Pacific Energy Fireplace Products Ltd. Duncan, British Columbia, Canada Certified for / Certifié pour Canada and U.S.A. MADE IN CANADA REPORT NO. 476-1096 (JUNE 95) FABRIQUE AU CANADA MODEL/ SERIES/ THE ESTATE MODELE: SERIE: FOR USE WITH/ NATURAL GAS/ LP GAS/ EN CASE D’EMPLOI AVEC:...
  • Page 36 - p a r t s . c o m Pacific Energy Fireplace Products Ltd. PO Box 1060, Duncan, B.C. V9L 3Y2 Phone: 250-748-1184 Web site: www.pacificenergy.bc.ca Printed in Canada...