INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING:
If the information in these
instructions is not followed exactly a fire or
explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical Switch.
• Do not use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
This appliance may be installed in an
aftermarket permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with
other gases unless a certified kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
120315-40
ESPRIT
INSTALLATION AND

OPERATING INSTRUCTIONS

MODEL: ESPR.BODYA
ESPRIT ZERO CLEARANCE
FIREPLACE
ESPR.BODYA
5056.201-A

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy ESPR.BODYA

  • Page 1: Operating Instructions

    This appliance is not convertible for use with other gases unless a certified kit is used. This appliance is suitable for installation in a MODEL: ESPR.BODYA bedroom or bed sitting room. ESPRIT ZERO CLEARANCE FIREPLACE 120315-40 ESPR.BODYA...
  • Page 2: Note For Massachucettes

    A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. 120315-40 ESPR.BODYA 5056.201-A...
  • Page 3: Table Of Contents

    Panel Installation/Removal ........ 29 Burner And Tray Installation/Removal ....30 Log Set Installation/Removal ......31 Glass Burner Kit Installation/Removal ....32 Intake Air Damper Installation ......33 Sales Codes ............34 Wiring Diagram ..........35 Rating Label ............36 5056.201-A ESPR.BODYA 120315-40...
  • Page 4: Caution

    Caution FOR YOUR SAFETY - Do not install or operate your Pacific Energy fireplace without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Pacific Energy Warranty and may prove hazardous. This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
  • Page 5: Safety

    • It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures. 5056.201-A ESPR.BODYA 120315-40...
  • Page 6: Owners Information

    OWNER’S INFORMATION Congratulations on your purchase of a Pacific Energy Gas Fireplace. Your fireplace has been professionally installed by: Dealer name: ______________________________ Phone Number: ____________________________ If you discover any problems with your gas fireplace contact your dealer immediately to have the unit repaired.
  • Page 7: Remote Control Operation

    LCD display (Fig. 1). The remote transmitter is powered by 3 AAA type batteries. A mode key is provided to index between the features and a thermostat key is used to turn on/off or index through thermostat functions (Fig. 1 & 2). Figure 1: Proflame2 Transmitter Figure 2: Transmitter LCD display 5056.201-A ESPR.BODYA 120315-40...
  • Page 8: Ifc Module

    The remote transmitter is now ready to use. Figure 4. On/Off switch. Position switch in the middle to use the hand-held remote control unit. Figure 5. On/Off switch cover Figure 3. IFC (integrated fireplace control) module. 120315-40 ESPR.BODYA 5056.201-A...
  • Page 9 This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP keys at the same time (fig.8).To de-activate this function, press the MODE and UP keys at the same time. Figure 8 5056.201-A ESPR.BODYA 120315-40...
  • Page 10 (Fig. 11). To adjust the set point, press the up or down arrow keys until the desired set point temperature Figure 12 is displayed on the LCD screen of the remote transmitter (Fig. 12). 120315-40 ESPR.BODYA 5056.201-A...
  • Page 11 (fig.14). Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode (CPI). Pressing the Down Arrow Key will return to IPI. A single “beep” will confirm the reception of the command. Figure 14: CPI/IPI Selection 5056.201-A ESPR.BODYA 120315-40...
  • Page 12: Warnings And Cautions

    Shock Hazard. Can cause severe injury or death This device is powered by line voltage. Do not try to repair this device. In no way is the enclosure to be tampered with or opened. Disconnect from line voltage before performing any maintenance. 120315-40 ESPR.BODYA 5056.201-A...
  • Page 13: Maintenance

    Do not strike or otherwise impact the glass in any way that may cause it to break. If the glass becomes cracked or broken it must be replaced before using the fireplace. Replacement door can be obtained from your nearest Pacific Energy dealer. Do not substitute with any other type.
  • Page 14 Viewing glass may be cleaned as necessary with fireplace glass cleaner. b) Exterior finish may be cleaned with mild soap and water. CAUTION: Do not use abrasive cleaners on glass or any other part of the fireplace. Do not clean glass when hot. 120315-40 ESPR.BODYA 5056.201-A...
  • Page 15: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION 5056.201-A ESPR.BODYA 120315-40...
  • Page 16: Installer Information

    Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or standard for Gas Equipped Recreational Vehicles and Mobile Housing , CSA Z240.4 Fig. 17: Framing Fig. 18: Fireplace Dimensions 120315-40 ESPR.BODYA 5056.201-A...
  • Page 17 INSTALLER INFORMATIO Fig. 19: Framing At The Corner Fig. 20: Minimum Clearance Corner Framing 5056.201-A ESPR.BODYA 120315-40...
  • Page 18: Clearances To Combustibles

    When the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Specified clearances shall be maintained from the top surface of carpeting, tile, etc. 120315-40 ESPR.BODYA 5056.201-A...
  • Page 19: Locating The Fireplace

    Due to high temperatures, do not locate this fireplace in areas of high traffic or near furniture or draperies. For places where a second side wall is specified, fireplace should be accessible for service Figure 23: Common Installation Location Figure 24: Framing Dimensions 5056.201-A ESPR.BODYA 120315-40...
  • Page 20: Surround Installation

    2. Install screen with the frame in slots on inner side of the surround base. 3. Install the surround front by positioning it so as to clear the notches and secure by applying downward pressure in order to engage the locking tabs. Figure 27: Surround Dimensions 120315-40 ESPR.BODYA 5056.201-A...
  • Page 21: Venting

    90° can be used without reducing horizontal run. For each additional 90° elbow, or an equal combination of elbows, reduce horizontal vent run by 2 feet. Ensure vent pipe is properly supported. Figure 28: Venting chart 5056.201-A ESPR.BODYA 120315-40...
  • Page 22: Vent Terminal Minimum Clearances

    INSTALLER Fireplace Dimensions Vent Terminal Minimum Clearances INFORMATION This fireplace is certified for use with 4” x 6-5/8”coaxial venting components only. It is permitted to only use certified venting for this appliance. 120315-40 ESPR.BODYA 5056.201-A...
  • Page 23: Venting Components

    Venting Components INFORMATIO NOTE: Mixing venting components from different manufacturers is inadvisable. Figure 29: 4”x6-5/8" Rigid Piping Cross Reference Chart Figure 1: 4”x6-5/8" Rigid Piping Cross Reference Chart Figure 30: 4”x6-5/8" Rigid Pipe Components Cross Reference Chart 5056.201-A ESPR.BODYA 120315-40...
  • Page 24: Plumbing And Electrical

    Figure 31A: Electrical Connection Electrical connection Open the access panel as seen in Figure 31A and connect the line wires to the supplied wires inside the junction box using marrettes. A licensed electrician must be used to make this connection. 120315-40 ESPR.BODYA 5056.201-A...
  • Page 25: Gas Supply

    Natural Gas Propane 2.55mm 30,000 btu/hr max. 22,000 btu/hr min. Minimum 5.0" WC 11.0" WC Maximum 13.9" WC 13.9" WC 1.52mm 26,000 btu/hr max. 22,000 btu/hr min. Manifold Pressure High 3.5" WC 10" WC 1.6" WC 6.4" WC 5056.201-A ESPR.BODYA 120315-40...
  • Page 26: Gas Pressure Testing Procedure

    VENTURI ADJUSTMENT SCREW Pilot Adjustment The pilot flame level can be adjusted by turning the adjustment screw, using a flat-tip screwdriver, seen on the valve in Figure 33. Figure 24: Valve Location Figure 32: Valve Figure 33: Valve 120315-40 ESPR.BODYA 5056.201-A...
  • Page 27: Propane Conversion

    The correct venturi settings are shown in Figure 36. Loosen the screw and slide the shutter. Tighten the screw, and return the burner into position Figure 36: Venturi Shutter 5056.201-A ESPR.BODYA 120315-40...
  • Page 28: Door Installation / Removal

    4. Remove baffle, rear panel and side panels. 5. Remove burner tray together with valve assembly. 6. Disconnect fan electrical wires and remove fan fasteners. Figure 38: Fan Installation/Removal 7. Remove fan out of the firebox assembly. 120315-40 ESPR.BODYA 5056.201-A...
  • Page 29: Panel Installation/Removal

    Figure 42. 5. Do panel removal in reverse order. Figure 40: Back Panel Figure 41: Side Panel Figure 42: Baffle Mounts 5056.201-A ESPR.BODYA 120315-40...
  • Page 30: Burner And Tray Installation/Removal

    Figure 44: Burner and lift the burner out of the unit. Embers Placement Place embers chunks in rock tray as seen in Figure 45. Do not block air openings and pilot elements with embers. Figure 45: Ember Placement 120315-40 ESPR.BODYA 5056.201-A...
  • Page 31: Log Set Installation/Removal

    Figure 46: Log Set Figure 47: Two Rear Logs Figure 48: Rear Log Set Figure 49: Left Side Log Figure 50: Front Logs Figure 52: Complete Setup Figure 51: Middle Log 5056.201-A ESPR.BODYA 120315-40...
  • Page 32: Glass Burner Kit Installation/Removal

    To install the optional rock set, simply place desired number of rocks into the fireplace pan as seen in Figure 54 making sure no rocks are in the flame when the unit is operating. Figure 53: Glass Installation Figure 54: Rocks Installation 120315-40 ESPR.BODYA 5056.201-A...
  • Page 33: Intake Air Damper Installation

    This damper can be closed to reduce the speed of the intake air and thus calm the flames to a more natural look. See Page 21 to check if damper required for installation. Fig 55 5056.201-A ESPR.BODYA 120315-40...
  • Page 34: Sales Codes

    LOUVERED SURROUND GREY........... ESPR.LVSGYA DESIGN OPTIONS TRANQUILITY ROCK SET ............ GASC.TRANQA METRO ROCK SET - BLACK ..........GASC.METROBKA METRO ROCK SET - GREY ..........GASC.METROGYA PERFORMANCE OPTIONS OPTIONAL BLOWER KIT ............ESPR.BLOWKITA LP CONVERSION KIT ............GASC.LPKIT 120315-40 ESPR.BODYA 5056.201-A...
  • Page 35: Wiring Diagram

    INSTALLER Wiring Diagram INFORMATIO Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Fig 56 5056.201-A ESPR.BODYA 120315-40...
  • Page 36: Rating Label

    INSTALLER Fireplace Dimensions Esprit Rating Label INFORMATION 120315-40 ESPR.BODYA 5056.201-A...
  • Page 37 ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ 5056.201-A ESPR.BODYA 120315-40...
  • Page 38 INSTALLER Fireplace Dimensions INFORMATION ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________ 120315-40 ESPR.BODYA 5056.201-A...
  • Page 39 INSTALLER INFORMATIO 5056.201-A ESPR.BODYA 120315-40...
  • Page 40 © 2015 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer Web site: www. pacificenergy.net 2975 Allenby Rd., Duncan, BC V9l 6V8...