If a Pipe Run requires 1/8" Drop (Slope) per foot for drainage,
how much total drop is required for a 25' Run?
KEySTRoKES
1. Enter the Slope (Drop):
2. Calculate the total drop (Offset):
calculating flow Rate
If you know the Area and Velocity, you can calculate the Flow
Rate. For this example, the Velocity is 5 feet per second, and
the Area is 1.8 square inches.
KEySTRoKES
1. Enter the Velocity:
2. Enter the Area:
Calculate Flow Rate (default is Gallons per Minute):
(Gallons per Minute)
(Cubic Feet per Minute)
(Cubic Feet per Second)
(Liters per Second)
(Cubic Meters per Second)
If you clear the display, you can recall the last Flow Rate shown.
KEySTRoKES
If you clear the calculator, you will only recall the last unit shown.
22 — P
C
lUmbinG
alC
ofST 0 fEET 3 - 1/8 INch
™ P
ro
DISPlAy
SlP 0 - 1/8 INch
DISPlAy
All clEARED
fPS 5
AREA 1.8 SQ INch
GPm 28.05195
cfm 3.75
cfS 0.0625
l/S 1.769803
m3/S 0.00177
DISPlAy
m3/S 0.00177
0.
0.