Not lit, means that the heat pump is not powered.
When the green light shines continuously, the heat pump has
power and is ready to produce heat or hot water.
Flashing green, means an active alarm.
4.3

Display

The display shows information about the heat pump's operation, status
and any alarms.
Symbols that show the heat pump status:
Symbol
F
12 – User manual VUBMA902
Meaning
HP
Indicates that the compressor is in operation.
LIGHTNING
Indicates that the auxiliary heater is in operation. The
number indicates what additional step is activated.
HOUSE
Indicates that the heat pump produces heat for the heat-
ing system.
TAP
Indicates that the heat pump produces heat for the
water heater.
FLOW SEN-
An F indicates that a flow sensor is installed.
SOR
CLOCK
Indicates that tariff control is active.
TANK
Indicates the level of hot water in the water heater. When
hot water is produced for the water heater, this is indica-
ted by a flashing icon for the tank. A lightning symbol by
the symbol indicates peak heating charging (anti-legion-
ella function).
SQUARE
Either indicates that the operating pressure switch has
deployed, or that the pressure pipe temperature has
reached its maximum temperature.
DEFROST
Displayed when defrosting is active (applies to DHP-A).