PROBLEM:
Switch on switch plate is bad.
SOLUTION:
Replace switch.
PROBLEM:
Heating element is bad.
SOLUTION:
Replace element.
SYMPTOM:
VACUUM MOTOR IS NOT WORKING PROPERLY:
PROBLEM:
Hose not connected tightly to upholstery tool or machine.
SOLUTION:
Connect hose tightly.
PROBLEM:
Drain valve is not shut completely.
SOLUTION:
Close drain valve completely.
PROBLEM:
Vacuum tank lid is not on tightly.
SOLUTION:
Secure the vacuum tank tightly.
PROBLEM:
Ball float is shut off.
SOLUTION:
Empty the vacuum tank of all wastewater.
PROBLEM:
Water is coming out of vacuum motor.
SOLUTION:
Use a low foaming detergent.
PROBLEM:
Upholstery tool is clogged with hair, carpet fibers and or debris.
SOLUTION:
Clean upholstery tool.
PROBLEM:
Switch on switch plate is bad.
SOLUTION:
Replace switch.
PROBLEM:
Vacuum motor armature is worn out.
SOLUTION:
Replace vacuum motor.