EGi Domos2 User Manual page 30

Hide thumbs Also See for Domos2:
Table of Contents

Advertisement

more adjustments
LANGUAGE SELECTION
Enables the menu language to be selected. To modify the service, do as follows:
1.
Press the key at the bottom twice for one second, until AUDIO is displayed.
2.
Press the key at the bottom again briefly and pass AUDIO until you reach MISCELL.
3.
Then press the right-hand side key ( ).
4.
Navigate through the options by pressing the lower part of the control unit, until LANGUAGE is displayed.
5.
Press for a longer period of time until the language is displayed.
6.
Press the left (–) or right-hand side ( ) to choose between the different languages available or automatic.
In automatic mode, the control units are configured in the language defined in the Central unit (see
Central unit documentation) if this option is available.
7.
Press the lower part of the control unit to confirm.
m i s c e l l
nd
2
st
1
SOFTWARE VERSION
If you need to make a technical query about the product, Technical Service may request you to supply the
equipment software version.
To find this out, do as follows:
1.
Press the key at the bottom twice for one second, until AUDIO is displayed.
2.
Press the key at the bottom again briefly and pass AUDIO until you reach MISCELL.
www.egiaudio.com
control unit
40220, 40221
l a n g u a g e
e n g l i s h
nd
st
2
1
st
1
3.
Then press the right-hand side key ( ).
4.
Keep the key ( ) pressed until you are in the menu.
5.
Navigate through the options by pressing the lower part of the control
unit, until VERS is displayed.
6.
The number displayed is the software version of the equipment.
m i s c e l l
SOS FUNCTION
The DOMOS2 system includes an SOS function.
This function, when you press the lower area of the control unit for 5 seconds,
or press the remote control (also for 5 seconds) (EGi ref. 40100 or 40130)
st
1
will activate a warning buzzer in the zone where the alarm occurred. If, within
about 5 seconds, this alarm has not been responded to by pressing the lower
area of the control unit for 2 seconds, the signal will be transmitted to the
entire installation and will remain active for 2 minutes if it is not cancelled
before this time through any control unit.
While the SOS mode is active, the control unit backlight will switch on and
off, the word SOS will flash on the screen and when the SOS is transmitted
to the rest of the installation, the rest of the control units will do the same.
30
V E R S 1
nd
2
st
1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Domos2 and is the answer not in the manual?

Table of Contents