EGi Domos2 User Manual page 10

Hide thumbs Also See for Domos2:
Table of Contents

Advertisement

40020, 40040, 40060
before starting
Once the DOMOS2 system has been correctly installed, the different modules must be configured for proper
performance whitin the system. Each room is called a ZONE.
This procedure will assign a zone to each control unit, so that the central unit will detect and assign functions
to each control unit, and intercom will be set.
RESET SYSTEM ZONES
If a reset of the installation has to be done, please proceed as follows:
1.
Press MENU key
several times until MISCELL. appears on the screen.
2.
Press (OK/+), and press the same key (OK/+) for 2 seconds.
3.
GAIN appears on the display.
4.
Press repeatedely MENU key
until SETUP appears on the screen. Then, press OK for 2 seconds.
The assigned zone assigned to the module will flash on the display.
5.
Navigate until RESET appears. Then, press OK for 2 seconds.
M I S C E L L .
A U T O
S E T U P
R E S E T
1
– – – –
www.egiaudio.com
central units
for DIN rail mounting
st
nd
1
2
G A I N
S E T U P
CLOCK CONFIGURATION
One of the central unit main functions is to manage the services provided by
the system. To make some of the services work properly, clock installation
must be correctly configured.
1.
Press MENU key
installation clock can be activated or deactivated by using (OK/+) or (NO/–).
2.
For time adjustment, press (OK) to activate installation clock and (OK)
again for clock adjustment (HOUR will flash).
3.
Modify the hour pressing (OK/+) or (NO/–).
4.
Press MENU key
NOTE:
You can abandon the programming at any time by pressing CANCEL
several times.
c l o c k
y e s
st
st
1
1
1
nd
2
10
until CLOCK appears on the screen. From here, the
to modify MINUTE the same way.
st
1
H O u r
M I N U T e
1 1
: 1 5
1 1 :
st
1
nd
2
nd
2
st
1
1 5
nd
2

Hide quick links: