Receiver Adjustment - Icom ID-1 Service Manual

Digital
Hide thumbs Also See for ID-1:
Table of Contents

Advertisement

5-4 RECEIVER ADJUSTMENT

ADJUSTMENT ITEM
SQUELCH
1
• Operating freq. : 1270.00 MHz
LEVEL
• Mode
[ SQL adjustment
• Connect an SSG to the antenna connector and
/FM thresh]
set as:
• Receiving
[ SQL adjustment
2
• Set an SSG as:
/FM tight]
• Receiving
1
AFC CENTER
• Operating freq. : 1270.00 MHz
[ AFC center
• Mode
voltage adjust-
• Connect an SSG to the antenna connector and
ment/FM]
set as:
• Receiving
2
[ AFC center
• Mode
voltage adjust-
• Receiving
ment /DV]
S-METER (FM)
1
• Operating freq. : 1270.00 MHz
[ S-meter
• Mode
adjustment
• Connect an SSG to the antenna connector and
/FM min]
set as:
• Receiving
[ S-meter
2
• Set an SSG as:
adjustment
/FM full]
• Receiving
S-METER (DV)
1
• Operating freq. : 1270.00 MHz
[ S-meter
• Mode
adjustment
• Set an SSG as:
/DV min]
• Receiving
2
[ S-meter
• Set an SSG as:
adjustment
/DV full]
• Receiving
S-METER (DD)
1
• Operating freq. : 1270.00 MHz
[ S-meter
• Mode
adjustment
• Set an SSG as:
/DD min]
• Receiving
[ S-meter
2
• Set an SSG as:
adjustment
/DD full]
• Receiving
*The output level of the standard signal generator (SSG) is indicated as the SSG's open circuit.
ADJUSTMENT CONDITION
: FM mode
Level
: 0.11 µV* (–126 dBm)
Modulation
: 1 kHz
Deviation
: 3.5 kHz
Level
: 0.18 µV* (–122 dBm)
: FM mode
Level
: 1 mV* (–47 dBm)
Modulation
: OFF
: DV mode
: FM mode
Level
: 0.18 µV* (–122 dBm)
Modulation
: OFF
Level
: 5.6 µV* (–92 dBm)
: DV mode
Level
: 0.18 µV* (–122 dBm)
Modulation
: OFF
Level
: 5.6 µV* (–92 dBm)
: DD mode
Level
: 1.6 µV* (–103 dBm)
Modulation
: OFF
Level
: 5.6 µV* (–92 dBm)
• Push [ENTER] on the connected computer key-
board to set to "SQL adjustment/FM thresh" level.
• Push [ENTER] on the connected computer key-
board to set to "SQL adjustment/FM tight" level.
• Push [ENTER] on the connected computer's key-
board to set to "AFC center voltage adjustment/
FM" level.
• Push [ENTER] on the connected computer key-
board to set to "AFC center voltage/DV" level.
• Push [ENTER] on the connected computer key-
board to set to "S-meter adjustment/FM min" level.
• Push [ENTER] on the connected computer key-
board to set to "S-meter adjustment/FM full" level.
• Push [ENTER] on the connected computer key-
board to set to "S-meter adjustment/DV min" level.
• Push [ENTER] on the connected computer key-
board to set to "S-meter adjustment/DV full" level.
• Push [ENTER] on the connected computer key-
board to set to "S-meter adjustment/DD min" level.
• Push [ENTER] on the connected computer key-
board to set to "S-meter adjustment/DD full" level.
5 - 7
OPERATION

Advertisement

Table of Contents
loading

Table of Contents